FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-3 Version Upgrade History
For the manufacturer’ serial number check method, refer to Appendix A-3-1.
Appendix A-3-5 Version upgrade history [FX3UC]
Version
Manufacturer’s
serial number
Contents of version upgrade
Ver. 2.70
107****
(July, 2010)
Supports the following 3 instructions:
VRRD(FNC85), VRSC(FNC86), IVMC(FNC275)
Supports connection of following analog volume expansion board:
-FX3U-8AV-BD
Supports the lower over-scale detection function of FX3U-4AD-ADP and FX3U-3A-ADP.
Ver. 3.00
115****
(May, 2011)
Supports storage of symbolic information.
Support of the setting "Read-protect the execution program" for block passwords.
Special block error condition (D8166) is added.
Supports connection of following memory cassette.
-FX3U-FLROM-1M
Version
Manufacturer’s
serial number
Contents of version upgrade
Ver. 1.00
41****
(January, 2004)
First product
Ver. 1.20
44****
(April, 2004)
Supports connection of the following special analog adapters:
-FX3U-4AD-ADP
-FX3U-4DA-ADP
Ver. 1.30
48****
(August, 2004)
Supports connection of the following special analog adapters:
-FX3U-4AD-PT-ADP
-FX3U-4AD-TC-ADP
Supports connection of the following special function block:
-FX3UC-4AD
Supports the following 3 instructions:
- SCL2 (FNC269), RWER (FNC 294), and INITER (FNC 295)
Adds function of the following instruction:
- DVIT (FNC151)
Ver. 2.20
55****
(May, 2005)
Supports the functions described as "Ver. 2.20 or later" in this manual.
Supports the following 28 instructions:
ZPUSH(FNC102), ZPOP(FNC103), WSUM(FNC140),WTOB(FNC141),
BTOW(FNC142),UNI(FNC143), DIS(FNC144), SORT2(FNC149), TBL(FNC152),
COMRD(FNC182), DUTY(FNC186), BK+(FNC192), BK-(FNC193),
BKCMP=(FNC194), BKCMP>(FNC195), BKCMP<(FNC196),
BKCMP<>(FNC197), BKCMP<=(FNC198), BKCMP>=(FNC199), STR(FNC200),
VAL(FNC201), INSTR(FNC208), FDEL(FNC210), FINS(FNC211),
DABIN(FNC260), BINDA(FNC261), RBFM(FNC278), WBFM(FNC279)
Adds function of the following 5 instructions:
SPD(FNC 56), DSZR(FNC150), DVIT(FNC151), ZRN(FNC156), PLSV(FNC157),
HCMOV(FNC189)
Supports connection of FREQROL-F700/A700 inverters supporting the following 5 instructions:
IVCK (FNC270), IVDR (FNC271), IVRD (FNC272), IVWR (FNC273), and IVBWR (FNC274)
Adds second entry code
(when GX Developer SW8.23Z (Ver. 8.23Z or later) is used).
Supports BFM initial value setting function
(when GX Developer SW8.23Z (Ver. 8.23Z or later) is used).
Mitigates restriction in writing during RUN
(when GX Developer SW8.23Z (Ver. 8.23Z or later) is used).
- Number of steps which can be changed by one-time write during RUN is changed.
127 steps 256 steps
- Handling of circuit blocks which can be changed by one-time write during RUN is changed.
Program of continuous circuit blocks having 127 steps or less
Program of circuit blocks having 256 steps or less in total
Ver. 2.30
5Y****
(November, 2005)
Adding the following instructions and function upgrade.
Adding MEP and MEF instructions
Function upgrade of MUL (FNC 22), DIV (FNC 23), and RS2 (FNC 87) instructions.
Ver. 2.41
79****
*1
(September, 2007)
•FX
3UC-MT/D(SS) (First product)
The baud rate "38400 bps" is supported in the RS and RS2 instructions, inverter
communication and computer link.
Ver. 2.53
84****
(April, 2008)
FX3UC-32MT-LT-2 (First product)