907
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-3 Version Upgrade History
31
FNC276-FNC279
Data
Transfer 3
32
FNC280-FNC289
High-Speed
Processing 2
33
FNC290-FNC299
Extension File
Register
34
FNC300-FNC305
FX
3U
-CF-ADP
35
SFC•STL
Programming
36
Interrupt
Function
37
Special Device
38
Error Code
A
Version Up
Information
B
Execution Times
*1. The FX3UC-32MT-LT supports Ver. 2.41 from the manufacturer's serial number "7X****" (October 2007).
*2. Available in Ver. 2.70 or later of FX
3UC-32MT-LT-2 PLC.
*3. This function is supported only in the FX
3UC-32MT-LT(-2).
→ For the manufacturer’ serial number check method, refer to Appendix A-3-1.
Ver. 2.61
*2
97****
(July, 2009)
• Supports the following 6 instructions:
FLCRT (FNC300), FLDEL (FNC301), FLWR (FNC302), FLRD (FNC303),
FLCMD (FNC304), FLSTRD (FNC305)
• Supports connection of the following special adapters:
-FX3U-3A-ADP
-FX3U-CF-ADP
• Supports the hardware error function of FX3U-4DA-ADP.
• Customer keyword / permanent PLC lock is supported.
Ver. 2.70
107****
(July, 2010)
•FX3UC-16MR/D-T, FX3UC-16MR/DS-T (First product)
• Supports the following 3 instructions:
VRRD(FNC85), VRSC(FNC86), IVMC(FNC275)
• Supports connection of the following analog volume expansion board:
-FX3U-8AV-BD
*3
• Supports the lower over-scale detection function of FX3U-4AD-ADP and FX3U-3A-ADP.
Ver. 3.00
115****
(May, 2011)
• Supports storage of symbolic information.
• Support of the setting "Read-protect the execution program" for block passwords.
• Special block error condition (D8166) is added.
• Supports connection of following memory cassette.
-FX3U-FLROM-1M
Version
Manufacturer’s
serial number
Contents of version upgrade