896
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-1 Programming Tool Applicability
English version
*1. Write during RUN is not possible with a SFC program.
*2. Write during RUN is not possible with a list program or a SFC program.
Programming tool PLC Version Remarks
GX Works2
*1
(SWDNC-GXW2-E)
FX3G Ver. 1.08J or later
Writing in the instruction and device ranges during RUN is supported in FX3G
PLCs Ver. 1.10.
FX3U/FX3UC
Ver. 1.08J or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs earlier than Ver. 2.70.
Ver. 1.48A or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs Ver. 2.70.
GX Developer
*2
(SWD5C-GPPW-E)
FX
3G
Ver. 2.00A or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLCs Ver. 1.00.
Ver. 5.00A or later
Writing in the instruction and device ranges during RUN is supported in FX1N
PLCs Ver. 1.00.
Ver. 8.72A or later
Writing in the instruction and device ranges during RUN is supported in FX
3G
PLCs earlier than Ver. 1.10.
Ver. 8.78G or later
Writing in the instruction and device ranges during RUN is supported in FX3G
PLCs Ver. 1.10.
FX3U/FX3UC
Ver. 7.00A or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLCs Ver. 3.00.
Ver. 8.18U or later
Writing in the instruction and device ranges during RUN is supported in FX3UC
PLCs earlier than Ver. 2.20.
Ver. 8.24A or later
Writing in the instruction and device ranges during RUN is supported in FX
3U and
FX
3UC PLCs earlier than Ver. 2.30.
Ver. 8.29F or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs earlier than Ver. 2.61.
Ver. 8.82L or later
Writing in the instruction and device ranges during RUN is supported in FX3U and
FX3UC PLCs Ver. 2.61.
FX-PCS/WIN-E
*2
FX3G Ver. 3.00 or later
Writing in the instruction and device ranges during RUN is supported in FX1N
PLCs Ver. 1.00.
FX3U/FX3UC
Ver. 1.00 or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLCs Ver. 1.00.
Ver. 3.10 or later
Writing in the instruction and device ranges during RUN is supported in FX2N
PLCs Ver. 3.00.