5 DIFFERENCES IN FLOW AT MACHINE STARTUP ADJUSTMENT
5.1 Differences in Operation Flow
23
5
5 DIFFERENCES IN FLOW AT MACHINE
STARTUP ADJUSTMENT
This section describes the differences in flow at machine startup adjustment.
5.1 Differences in Operation Flow
An operation flowchart is shown below. There is no difference in the basic operation flow till the test operation among LE-
40MTA, B(-E), LE-30CTN(A), and LE7-40GU-L.
5.2 Difference in Operation Mode
LE7-40GU-L has the following operation modes.
Initial setting mode
• The LE7-40GU-L has an initial setting mode and is set in the initial setting mode from the factory shipment until the initial
setting completion operation is executed. In the initial setting mode, the setting items that are indispensable for the
operation of the tension controller are set in order. The LE-30CTN(A) does not have a function corresponding to the initial
setting mode.
• The items that can be set in the initial setting mode differ between LE-40MTA, B(-E) and LE7-40GU-L. The parameters that
can be set in the initial setting mode are compared below. The parameters that can not be set should be changed in
adjustment mode.
Mode Explanation Function availability
LE-40MTA, B(-E) LE-30CTN(A)
Initial setting mode Initial setting mode at startup of equipment
Adjustment Mode Parameter detail setting mode
Operation mode Yes
Parameter Setting location
LE-40MTA, B(-E) LE7-40GU-L
Password registration Initial Setting Adjustment
Tension display unit setting Initial setting/engineer Initial setting/adjustment
Selection of control target reel Initial setting/engineer Adjustment
Number of control target reels (selection of two-reel's
switching function)
Initial setting/engineer Initial setting/adjustment
Taper setting Initial setting/engineer Adjustment
Actuator setting Initial setting/engineer Adjustment*
*1
Usage of stall function Initial setting/engineer Adjustment
I/O terminal function setting Initial setting/engineer Adjustment
Full scale tension setting Initial setting/engineer Initial setting/adjustment
Zero span adjustment of tension detector Initial setting/engineer Initial setting/adjustment
(2) Controller settings
• Initial setting
• Tension detector setting
Stop
(5) Parameter
setting as needed
(4)
Operation
verification by
automatic operation
(3) Drive system
verification by
manual operation
(1)
Controller
installation
and wiring