    Joshua GrayAug 1, 2025
    Why is my Mitsubishi Electric MDS-E showing overvoltage?
    • A
      Ashley WalkerAug 1, 2025
      The overvoltage error in Mitsubishi Electric Control Systems occurs because the bus voltage in the main circuit has exceeded the allowable value.
  • T
    Tom WarrenAug 5, 2025
    Why does my Mitsubishi Electric MDS-E Control Systems have excessive speed error?
    • S
      Susan CarterAug 5, 2025
      Excessive speed error in Mitsubishi Electric Control Systems means that the difference between the actual speed and the command speed continued for longer than the excessive speed deviation timer setting.
  • J
    Jessica MitchellAug 9, 2025
    What causes Mitsubishi Electric Control Systems to show grounding error?
    • C
      Christopher YoungAug 9, 2025
      A grounding error in Mitsubishi Electric Control Systems indicates that the motor power cable is in contact with FG (Frame Ground).
  • V
    vaughnrachelAug 13, 2025
    What causes initial magnetic pole position detection error in Mitsubishi Electric MDS-E Control Systems?
    • M
      Melissa YorkAug 13, 2025
      The initial magnetic pole position detection error in Mitsubishi Electric Control Systems occurs when the servo ON has been set before the magnetic pole shift amount is set in the built-in motor which uses the absolute position encoder.
  • J
    James WeaverAug 18, 2025
    What causes a Mitsubishi Electric MDS-E NC-DRV communication CRC error?
    • S
      smithtylerAug 18, 2025
      An NC-DRV communication CRC error in Mitsubishi Electric Control Systems means that the data received from the NC was outside the setting range.
  • T
    Thomas LyonsAug 22, 2025
    What does Mitsubishi Electric MDS-E Control Systems memory error 1 mean?
    • K
      Kim WashingtonAug 22, 2025
      Memory error 1 in Mitsubishi Electric Control Systems indicates that a hardware error was detected during the power ON self-check.
  • R
    Robert CalderonAug 27, 2025
    What does axis selection error mean in Mitsubishi Electric Control Systems?
    • J
      John ParkerAug 27, 2025
      An axis selection error in Mitsubishi Electric Control Systems means that the axis selection rotary switch has been incorrectly set.

Mitsubishi Electric MDS-E Series Specifications

General IconGeneral
CategoryControl Systems
SeriesMDS-E Series
Position ControlYes
Speed ControlYes
Torque ControlYes
Protection ClassIP20