Learning to Use the FX Family for Positioning Control Inverter Drive Control
4 - 32
MITSUBISHI ELECTRIC
Function Number Description
Writing
parameters to
the inverter
while the PLC is
in RUN mode.
The maximum frequency (Pr. 1) is specified
The maximum frequency (Pr. 1) is set to "120 Hz"
The minimum frequency (Pr. 2) is specified
The minimum frequency (Pr. 2) is set to "5 Hz"
The acceleration time (Pr. 7) is specified
The acceleration time (Pr. 7) is set to "1 sec"
The deceleration time (Pr. 8) is specified
The deceleration time (Pr. 8) is set to "1 sec"
The parameters are written at one time
[Contents of D200–D207 Pr. 1, Pr. 2, Pr. 7 and Pr. 8]
The maximum frequency (Pr. 1) is set to "120 Hz" [K12000 Pr. 1]
The minimum frequency (Pr. 2) is set to "5 Hz" [K500 Pr. 2]
The acceleration time (Pr. 7) is set to "1 sec" [K10 Pr. 7]
The deceleration time (Pr. 8) is set to "1 sec" [K10 Pr. 8]
Reset driving of write instruction
Tab. 4-22:
Description of the program example in fig. 4-21