102
APPX
Appendix 1 Instruction Replacement List
TKY TKY Create the program using the input
device (X).
DTKY DTKY
HKY HKY
DHKY DHKY
ARWS ARWS
ASC ASC
PR PR
RS RS Correct the program to use RS2
instruction.
VRRD VRRD
VRRDP VRRDP
VRSC VRSC
VRSCP VRSCP
INT INT Correct the program to use FLT2INT
instruction.
INTP INTP Correct the program to use
FLT2INTP instruction.
DINT DINT Correct the program to use
FLT2DINT instruction.
DINTP DINTP Correct the program to use
FLT2DINTP instruction.
DTBL DTBL Correct the program to use TBL
instruction.
ZRN ZRN Correct the program to use DSZR
instruction. Use the same device for
near-point dog signal and zero point
signal of the DSZR instruction, and
set the zero point signal count start
time to the rear end and the zero
point signal count to 1.
DZRN DZRN Correct the program to use DDSZR
instruction. Use the same device for
near-point dog signal and zero point
signal of the DDSZR instruction, and
set the zero point signal count start
time to the rear end and the zero
point signal count to 1.
RD3A RD3A Correct the program to use FROM
instruction.
RD3AP RD3AP Correct the program to use FROMP
instruction.
WR3A WR3A Correct the program to use TO
instruction.
WR3AP WR3AP Correct the program to use TOP
instruction.
COMRD COMRD
COMRDP COMRDP
DHSCT D
HSCT Set the high-speed comparison table
or multi-point output high-speed
comparison table in the module
parameter “High-speed I/O”.
SAVER SAVER Correct the program to use
ERWRITE instruction.
INITR INITR Correct the program to use FMOV
instruction. Correct the program to
collectively initialize (clear to 0) the
required number of points of the file
register (R).
FX3 Series MELSEC iQ-F Remarks