APPX
Appendix 3 Device Replacement List
109
A
*1 When the latch range of the device for keep of the FX3 Series is changed, if necessary, change the latch range or reset the devices. The
changing of the latch range is only supported by the FX5U/FX5UC.
*2 Set the parameter with “Option Battery Setting” under [Parameter] [FX5UCPU] [CPU Parameter] [Memory/Device Setting]
[Device/Label Memory Area Setting].
*3 Set the interrupt setting by the parameter accordingly.
*4 The parameter is reflected in [Parameter] [FX5UCPU] or [FX5UJCPU] [Module Parameter] [High Speed I/O] [Input Function]
[General/Interrupt/Pulse Catch].
Also, the parameter is reflected in [Module Parameter] [Input Response Time Setting].
*5 The parameter is reflected in [Parameter] [FX5UCPU] or [FX5UJCPU] [CPU Parameter] [Interrupt Settings] [Fixed Interval
Setting].
Interrupt
pointer
*3
Input interrupt
(delay
interrupt)
I00
I10
I20
I30
I40
I50
I0 to I5 Replaced as follows.
*4
I00 I0
I10 I1
I20 I2
I30 I3
I40 I4
I50 I5
= 1: Rise interrupt
= 0: Fall interrupt
When is 2 to 9, it will be replaced
with P4095.
The MELSEC iQ-F Series does not
support the delay interrupt function.
(There is no recommended substitute
function.)
Replaced as follows.
*4
I00 I0
I10 I1
I20 I2
I30 I3
I40 I4
I50 I5
= 1: Rise interrupt
= 0: Fall interrupt
When is 2 to 9, it will be replaced
with P4095.
The MELSEC iQ-F Series does not
support the delay interrupt function.
(There is no recommended substitute
function.)
Timer interrupt I6
I7
I8
I28 to I30 Replaced as follows.
*5
I6 I28
I7 I29
I8 I30
= 1 to 99: Execution interval
(ms)
Replaced as follows.
*5
I6 I28
I7 I29
I8 I30
= 1 to 99: Execution interval
(ms)
Counter
interrupt
I010
I020
I030
I040
I050
I060
I16 to I21 Replaced as follows.
I010 I16
I020 I17
I030 I18
I040 I19
I050 I20
I060 I21
Replaced as follows.
I010 I16
I020 I17
I030 I18
I040 I19
I050 I20
I060 I21
Module access device Module number (0
to 7)
BFM number (0 to
32766)
■FX5U/FX5UC
• Module number
(1 to 16)
• BFM number (0 to
65535)
■FX5UJ
• Module number
(1 to 8)
• BFM number (0 to
65535)
The conversion method can be
selected. (FX5U: Refer to Page
70 Operation Method for Replacing
Projects. FX5UC: Refer to Page
85 Operation Method for Replacing
Projects.)
The conversion method can be
selected. (Refer to Page 56
Operation Method for Replacing
Projects.)
Decimal constant 16-bit: K−32768 to
K32767
32-bit:
K−2147483648 to
K2147483647
16-bit: K−3
2768 to
K32767
32-bit:
K−2147483648 to
K2147483647
Hexadecimal constant 16-Bit: H0 to HFFFF
32-Bit: H0 to
HFFFFFFFF
16-Bit: H0 to HFFFF
32-Bit: H0 to
HFFFFFFFF
Real constant −1.02
128
to
−1.02
−126
, 0,
1.02
−126
to
1.02
128
−1.02
128
to
−1.02
−126
, 0,
1.02
−126
to
1.02
128
Character string constant 32 single-byte
characters
255 single-byte
characters
Device name FX3U, FX3UC After
conversion to
the FX5U,
FX5UC, or
FX5UJ
Precautions
In the case of FX5U and
FX5UC
In the case of FX5UJ