Lists indoor unit models, capacity, and connected outdoor units.
Specifies operating temperature ranges for cooling and heating for different unit types.
Provides usage guidelines and cautions for fresh air intake type indoor units.
Details technical specifications like capacity, power, dimensions, and operating range.
Shows detailed dimensions and installation clearances for standard type indoor units.
Provides the wiring diagram for standard type indoor units, including component explanations.
Presents sound pressure level data in dB(A) across different frequency bands for various indoor unit models.
Shows fan performance curves relating airflow rate to static pressure for indoor unit models.
Lists technical specifications for PUHY outdoor units, including piping, control, and dimensions.
Provides detailed dimensions and installation clearances for the PUHY-P250YHM-A outdoor unit.
Presents sound pressure level data in dB(A) across frequency bands for the PUHY-P250YHM-A.
Details optional twinning kits for combining multiple outdoor units.
Provides cooling capacity correction factors based on indoor and outdoor temperatures.
Graphs showing cooling and heating capacity correction factors based on piping length.
Graphs showing input correction factors based on the ratio of cooling or heating capacity.
Describes the MA Remote Controller, its functions, and dimensions.
Lists essential requirements for the installation site of outdoor units.
Lists site requirements for installing indoor units to ensure proper performance.
Details steps for installing indoor units, including handling and anchoring.
Shows internal component layouts for PFAV-P250/300/500/600VM-E indoor units.
Specifies copper pipe types, sizes, and radial thickness requirements for R410A systems.
Explains how to calculate and charge refrigerant for extended piping systems.
Shows the external wiring diagram for a system with PUHY-P250 and PFAV-P300 units.
Details wire sizes, capacities, and switch requirements for power supply.
Describes M-NET transmission and remote controller cable types and maximum lengths.
Shows sample wiring for a system using an MA remote controller.
Details start/stop control and power failure recovery settings for indoor units.
Explains emergency operation modes and troubleshooting for outdoor units.
Discusses the properties of R410A refrigerant and its safety implications.
Details critical concentration limits and countermeasures for refrigerant leaks.