EasyManua.ls Logo

Mitsubishi Electric PUHZ-P250YHA3R3 User Manual

Mitsubishi Electric PUHZ-P250YHA3R3
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SERVICE MANUAL
No. OCH424
REVISED EDITION-E
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
R410A
October 2011
Outdoor unit
[Model names]
PUHZ-P200YHA
PUHZ-P250YHA
PUHZ-P200YHA3
PUHZ-P250YHA3
[Service Ref.]
PUHZ-P200YHA
PUHZ-P250YHA
PUHZ-P200YHA3
PUHZ-P200YHA3R1
PUHZ-P200YHA3R2
PUHZ-P200YHA3R3
PUHZ-P250YHA3
PUHZ-P250YHA3R1
PUHZ-P250YHA3R2
PUHZ-P250YHA3R3
PUHZ-P200YHA3R1/R2/R3
PUHZ-P250YHA3R1/R2/R3
Note:
This manual describes only
service data of the outdoor units.
RoHS compliant products have
<G> mark on the spec name plate.
CONTENTS
1. TECHNICAL CHANGES
.................................
2
2. REFERENCE MANUAL
..................................
2
3. SAFETY PRECAUTION
..................................
3
4. FEATURES
......................................................
6
5. SPECIFICATIONS
...........................................
7
6. DATA
...............................................................
8
7. OUTLINES AND DIMENSIONS
....................
10
8. WIRING DIAGRAM
.......................................
12
9. WIRING SPECIFICATIONS
..........................
13
10.
REFRIGERANT SYSTEM DIAGRAM
...............
18
11. TROUBLESHOOTING
...................................
20
12. FUNCTION SETTING
....................................
70
13.
MONITORING THE OPERATION DATA BY THE REMOTE CONTROLLER
....
77
14. EASY MAINTENANCE FUNCTION
..............
87
15. DISASSEMBLY PROCEDURE
.....................
90
PARTS CATALOG (OCB424)
Revision:
"11-10 FUNCTION OF SWITCHES,
CONNECTORS AND JUMPERS"
has been modified in REVISED
EDITION-E. (See page 65)
Some descriptions have been
modified.
Please void OCH424
REVISED EDITION-D.

Questions and Answers:

Mitsubishi Electric PUHZ-P250YHA3R3 Specifications

General IconGeneral
BrandMitsubishi Electric
ModelPUHZ-P250YHA3R3
CategoryAir Conditioner
LanguageEnglish

Summary

Technical Changes

Safety Precaution

3-1. Always Observe For Safety

General safety precautions for repair service and during operation.

3-2. Cautions Related to New Refrigerant

Specific safety guidelines for R410A refrigerant use.

Features

Chargeless System

Description of the pre-charged refrigerant system for easier installation.

Specifications

Data

6-1. Refilling Refrigerant Charge

Refrigerant charge amounts based on piping length.

6-2. Compressor Technical Data

Technical data for the compressor.

6-3. Noise Criterion Curves

Graphical noise level data.

6-4. Standard Operation Data

Operational data for different matching conditions and modes.

Outlines and Dimensions

1 Free Space Requirements

Recommended clearances around the unit for installation and operation.

2 Service Space Requirements

Required space for maintenance access.

3 Foundation Bolts

Specifications for unit mounting bolts.

4 Piping-Wiring Directions

Directions for piping and wiring connections.

Piping Knockout Hole Details

Diagrams of knockout hole locations.

Wiring Diagram

Model Select

DIP switch settings for model selection.

Wiring Specifications

9-1. Field Electrical Wiring (Power Wiring)

Power wiring specs for the outdoor unit.

9-2. Separate Indoor/Outdoor Unit Power Supplies

Wiring configurations for separate power supplies.

9-3. Indoor – Outdoor Connecting Cable

Specifications for the connecting cable.

9-4. M-NET Wiring Method

Guidelines for M-NET communication wiring.

Refrigerant System Diagram

Refrigerant Recovering and Test Run

10-1. Refrigerant Recovering (Pump Down)

Procedure for recovering refrigerant from the system.

10-2. Start and Finish of Test Run

Instructions for performing a test run operation.

Troubleshooting

11-1. Troubleshooting Summary

Overview of troubleshooting based on error codes.

11-2. Check Point Under Test Run

Pre-test run checks and important points.

11-3. How to Proceed "Self-Diagnosis"

Procedures for initiating and interpreting self-diagnosis.

11-4. Self-Diagnosis Action Table

Detailed table linking error codes to causes and actions.

11-5. Troubleshooting by Inferior Phenomena

Diagnosing issues based on observed symptoms.

Function Setting

12-1. Unit Function Setting by the Remote Controller

How to set unit functions using the remote controller.

12-1-1. Selecting Functions Using the Wired Remote Controller

Procedure for wired remote controller function selection.

12-1-2. Selecting Functions Using the Wireless Remote Controller (Type C)

Procedure for wireless remote controller function selection.

12-2. Function Selection of Remote Controller

Detailed options for remote controller function selection.

Monitoring Operation Data

13-1. How to "Monitor the Operation Data"

Steps to monitor operation data via remote controller.

13-2. Request Code List

List of request codes and their data.

13-2-1. Detail Contents in Request Code

Detailed explanations for specific request codes.

Easy Maintenance Function

14-1. Maintenance Mode Operation Method

Procedures for activating and using maintenance mode.

14-2. Guide for Operation Condition

Guide to checking operation conditions and diagnosing performance.

Disassembly Procedure

1. Removing the Service Panel and Top Panel

Steps to remove service and top panels.

3. Removing the Electrical Parts Box

Steps to remove the electrical parts box.

11. Removing the Compressor (MC)

Steps to remove the compressor.

12. Removing the Accumulator

Procedure to remove the accumulator.

Related product manuals