EasyManua.ls Logo

Mitsubishi Electric PUHZ-P250YKAR1.UK User Manual

Mitsubishi Electric PUHZ-P250YKAR1.UK
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
SERVICE MANUAL
R410A
Outdoor unit
[Model Name]
PUHZ-P200YKA
PUHZ-P250YKA
[Service Ref.]
PUHZ-P200YKA.UK
PUHZ-P200YKAR1.UK
PUHZ-P250YKA.UK
PUHZ-P250YKAR1.UK
PARTS CATALOG (OCB582)
CONTENTS
TECHNICAL CHANGES ···································· 2
1. REFERENCE MANUAL ································· 3
2. SAFETY PRECAUTION ································· 3
3. FEATURES ····················································· 7
4. SPECIFICATIONS ·········································· 8
5. DATA ······························································· 9
6. OUTLINES AND DIMENSIONS ··················· 12
7. WIRING DIAGRAM ······································ 13
8. WIRING SPECIFICATIONS ·························· 14
9.
REFRIGERANT SYSTEM DIAGRAM
············· 19
10. TROUBLESHOOTING ·································· 21
11. FUNCTION SETTING ··································· 75
12.
MONITORING THE OPERATION DATA BY THE REMOTE CONTROLLER
···· 83
13. EASY MAINTENANCE FUNCTION ············· 92
14. DISASSEMBLY PROCEDURE ····················· 95
Note:
•Thismanualdescribesservice
dataoftheoutdoorunitsonly.
No. OCH582
REVISED EDITION-B
June 2015
•PleasevoidOCH582
REVISEDEDITION-A.
Revision:
•
Added
PUHZ-P200YKAR1.UKand
PUHZ-P250YKAR1.UKin
REVISEDEDITION-B.
•Somedescriptionshavebeen
modified.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric PUHZ-P250YKAR1.UK and is the answer not in the manual?

Mitsubishi Electric PUHZ-P250YKAR1.UK Specifications

General IconGeneral
BrandMitsubishi Electric
ModelPUHZ-P250YKAR1.UK
CategoryAir Conditioner
LanguageEnglish

Summary

2 SAFETY PRECAUTION

2-1. ALWAYS OBSERVE FOR SAFETY

Before obtaining access to terminal, all supply circuits must be disconnected.

2-2. CAUTIONS RELATED TO NEW REFRIGERANT

Cautions for units utilizing refrigerant R410A.

2-3. PRECAUTIONS WHEN REUSING EXISTING R22 REFRIGERANT PIPES

Flowchart to determine if existing pipes can be used and if a filter drier is necessary.

3 FEATURES

4 SPECIFICATIONS

5 DATA

5-1. REFILLING REFRIGERANT CHARGE

Table showing refrigerant charge amounts for different piping lengths.

5-2. ADJUSTING THE AMOUNT OF REFRIGERANT

Guidelines for adjusting refrigerant charge based on piping length.

6 OUTLINES AND DIMENSIONS

7 WIRING DIAGRAM

8 WIRING SPECIFICATIONS

9 REFRIGERANT SYSTEM DIAGRAM

10 TROUBLESHOOTING

10-1. TROUBLESHOOTING

Summary of check codes and actions for service based on reoccurring troubles.

10-3. HOW TO PROCEED "SELF-DIAGNOSIS"

Steps for performing self-diagnosis using the remote controller.

10-4. SELF-DIAGNOSIS ACTION TABLE

Table detailing actions for detected abnormalities when power is applied.

11 FUNCTION SETTING

12 MONITORING THE OPERATION DATA BY THE REMOTE CONTROLLER

13 EASY MAINTENANCE FUNCTION

14 DISASSEMBLY PROCEDURE

Related product manuals