QCPU User's Manual
(Hardware Design, Maintenance and Inspection)
-Q00(J)CPU -Q26UD(E)HCPU
-Q01CPU -Q26UDVCPU
-Q02(H)CPU -Q50UDEHCPU
-Q06HCPU -Q100UDEHCPU
-Q12HCPU
-Q25HCPU
-Q02PHCPU
-Q06PHCPU
-Q12PHCPU
-Q25PHCPU
-Q12PRHCPU
-Q25PRHCPU
-Q00U(J)CPU
-Q01UCPU
-Q02UCPU
-Q03UD(E)CPU
-Q03UDVCPU
-Q04UD(E)HCPU
-Q04UDVCPU
-Q06UD(E)HCPU
-Q06UDVCPU
-Q10UD(E)HCPU
-Q13UD(E)HCPU
-Q13UDVCPU
-Q20UD(E)HCPU

Table of Contents

Questions and Answers

  • D
    Deanna ParkerAug 17, 2025
    What to do if Mitsubishi Electric Q04UDVCPU error code 1128H or 112EH is output?
    • C
      christopher76Aug 17, 2025
      If you're getting error code 1128H or 112EH when connecting your Mitsubishi Electric Controller with the MELSEC iQ-R series, here's what you should do: * First, double-check the "External Device Configuration" settings for the connection number, as there might be an error there. * Second, verify the network camera wiring, ensuring the correct Ethernet port is used when connecting the network camera to the RJ71EN71 or RnENCPU. * Finally, review the program to ensure multiple FBs aren't simultaneously executed to a single network camera.
  • A
    andrew12Aug 20, 2025
    What to do if Mitsubishi Electric Controller error code 41B9H or 41A6H is output?
    • M
      Mark FrazierAug 20, 2025
      If you encounter error code 41B9H or 41A6H while connecting your Mitsubishi Electric Controller with the MELSEC-Q series, take these steps: First, check the "Open Setting" to ensure the connection number settings are correct. Second, review the program to confirm that multiple FBs aren't being executed simultaneously to a single network camera.
  • E
    Elizabeth RiveraAug 22, 2025
    What to do if no video file can be saved in the Mitsubishi Electric Q04UDVCPU Controller network storage?
    • T
      Thomas BakerAug 22, 2025
      If your Mitsubishi Electric Controller isn't saving video files to the network storage, consider the following: If the same port number is set to the programmable controllers in "External Device Configuration", the simultaneous socket communications cannot be performed, so set different port numbers to each programmable controller and execute the FB again. Also, the open processing may have failed to complete at the specified connection number, so try restarting the programmable controller and the network camera, then execute the FB again.
  • E
    Eric HenryAug 25, 2025
    Why is Mitsubishi Electric Controller time not setting to the network camera?
    • H
      Heather McdanielAug 26, 2025
      If the time of your programmable controller isn't being reflected on the network camera, it may be that the time of the programmable controller is not reflected on the network camera side. Try closing the configuration tool of the network camera and then execute the FB again.
  • D
    Danny HallAug 28, 2025
    What to do if Mitsubishi Electric Q04UDVCPU FB ends with error C1B1H?
    • S
      simmonsscottAug 28, 2025
      If the Mitsubishi Electric Controller FB ends with error C1B1H, set the constant scan time to 500ms or lower, or leave it blank, and then execute the FB again.
  • R
    Rhonda WarrenAug 31, 2025
    What to do if the POWER LED does not turn on for Mitsubishi Electric Q04UDVCPU?
    • L
      Laura GilbertAug 31, 2025
      If the MODE LED of the CPU module is on, it indicates that the power supply module has failed and needs replacement. Ensure the power supply voltage is within the specified range. If the internal current consumption exceeds the rated output current, reexamine the system configuration. If the POWER LED turns on after removing all modules except the power supply module, repeatedly supply power, adding modules back one by one to identify the failed module.
  • M
    Michael Alvarado PhDSep 2, 2025
    Why is the Ethernet communication not possible through direct connection with my Mitsubishi Electric Q04UDVCPU Controller?
    • Z
      zmillerSep 2, 2025
      Ensure the CPU module is directly connected to the programming tool with a single cable. Verify that the settings on the connected device (personal computer) are correct. Also, check that 'Ethernet Port Direct Connection' is selected for the PLC side I/F PLC Module in the Transfer Setup setting of the programming tool.
  • T
    Tonya RiveraSep 5, 2025
    What should I do if communication is slow or unstable on my Mitsubishi Electric Controller?
    • J
      James WillisSep 5, 2025
      First, ensure that there are no duplicate IP addresses and correct any that are found. Next, verify that the number of UDP connections does not exceed the limit set in the open setting for MELSOFT connection and the MC protocol. Finally, if the issue persists, take noise reduction measures, as the communication of other devices besides the CPU module might be unstable.
  • B
    Brian FloresSep 8, 2025
    What to do if the output load does not turn on in Mitsubishi Electric Q04UDVCPU?
    • M
      Matthew Burton Jr.Sep 8, 2025
      Check the power supply load wiring and recover the power supply if voltage for the power supply load is not added. If the inrush current has exceeded the specified value when the maximum number of outputs turns on simultaneously, change the output relay number and keep the load maximum simultaneous on current within the specified value.
  • A
    Amanda RodriguezSep 10, 2025
    Why MODE LED does not turn on in Mitsubishi Electric Q04UDVCPU?
    • U
      underwoodkatherineSep 12, 2025
      The MODE LED might not turn on because the forced ON/OFF is set; cancel the forced ON/OFF. Another reason could be an improper connection direction of the extension cable (OUT-OUT); connect the extension cable properly. Finally, ensure AC power is supplied to the power supply module.

Mitsubishi Electric Q04UDVCPU Specifications

General IconGeneral
SeriesQ Series
ModelQ04UDVCPU
Number of I/O Points4096 points
Data Memory128K words
SD Memory Card InterfaceYes
USB InterfaceYes
Power Supply24V DC
Operating Temperature0 to 55 °C
Storage Temperature-25 to 75°C
Humidity5 to 95%RH, non-condensing
Vibration Resistance10 to 57 Hz
Shock Resistance147m/s², 3 times in each of the X, Y, and Z directions
TypeProgrammable Logic Controller (PLC)
Communication PortsRS-232