EasyManua.ls Logo

Mitsubishi Electric R16MTCPU - Target Position Change Request: CHGP

Mitsubishi Electric R16MTCPU
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 OPERATION CONTROL PROGRAMS
4.15 Motion-Dedicated Functions
211
4
Target position change request: CHGP
Setting data
Usable Data
: Usable
Description, data type of result
The CHGP instruction cannot be used for the command generation axis under advanced synchronous control.
Format Number of basic steps Usable steps
F/FS G
CHGP((S1), (S2), (S3)) 11 
Setting
data
Usable Data
Bit
device
Word device Constant Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
16-bit
integer
type
(K/H)
32-bit
integer
type
(K/H, L)
64-bit
floating
point
type (K)
(S1) 
(S2) 
(S3) 
Setting data Description Data type of result
(S1) Axis No. to which target position change request will be given
(S2) Specified method of changed address
0: Address method
1: Movement method
(S3) Starting No. of device to store target position change value