4 OPERATION CONTROL PROGRAMS
4.19 Other Instructions
273
4
Write buffer memory data to head module: RTO
■Usable data
: Usable
■Description, data type of result
• (n) words of data from the device specified with (S) are written to the address specified with (D3) and after of the buffer
memory in the intelligent function module specified with (D2). The intelligent function module is mounted to the target
SSCNET/H head module specified with (D1). After writing completion of the device data, the complete bit device
specified with (D4) turns ON.
Format Number of basic steps Usable steps
F/FS G
RTO(D1), (D2), (D3), (S), (n), (D4) 21
Setting
data
Usable Data
Bit
device
Word device Constant Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
16-bit
integer
type
(K/H)
32-bit
integer
type
(K/H, L)
64-bit
floating
point
type (K)
(D1)
(D2)
(D3)
(S)
(n)
(D4)
Setting data Description Data type of result
(D1) RIO Axis No. of the target SSCNET/H head module (601 to 608)
(D2) First I/O No. of the intelligent function module which writes data.
(00 to FEH: First 2 digits when I/O No. is 3 digits)
(D3) First address of the buffer memory of the intelligent function module which writes data.
(S) Start device No. which writing data are stored.
(n) Number of words to be written (1 to 32767)
(D4) Complete devices
(D4+0): Self CPU device is made to turn ON by the writing completion.
(D4+1): Self CPU device is made to turn ON by the writing abnormal completion. ("D4+0" also turns ON at
the abnormal completion)
H0000
H0005
H000A
H0000
(S)
H0000
H0005
H000A
H0000
(D3)
(D2)
(D1)
Device memory
Write the data
of a part for
(n) words
Intelligent
function module
buffer memory
SSCNET
µ
/H head module