134
3 MAJOR POSITIONING CONTROL
3.2 Setting the Positioning Data
Setting positioning data
When using current value changing, set the following positioning data.
: Always set, : Set as required, : Setting not required
*1 Refer to the following for information on the setting details.
Page 445 Positioning Data
Setting item Setting required/not required
[Da.1] Operation pattern
[Da.2] Control method
(Set the current value changing.)
[Da.3] Acceleration time No.
[Da.4] Deceleration time No.
[Da.6] Positioning address/movement amount
(Set the address to be changed.)
[Da.7] Arc address
[Da.8] Command speed
[Da.9] Dwell time/JUMP destination positioning data No.
[Da.10] M code/Condition data No./Number of LOOP to LEND repetitions/
Number of pitches
[Da.20] Axis to be interpolated No.1
[Da.21] Axis to be interpolated No.2
[Da.22] Axis to be interpolated No.3
[Da.27] M code ON signal output timing
[Da.28] ABS direction in degrees
[Da.29] Interpolation speed designation method