8 CONTROL SUB FUNCTIONS
8.9 Other Functions
279
8
Precautions during control
If the skip signal is turned ON at the last of an operation, a deceleration stop will occur and the operation will be terminated.
When a control is skipped (when the skip signal is turned ON during a control), the positioning complete signals will not turn
ON.
When the skip signal is turned ON during the dwell time, the remaining dwell time will be ignored, and the next positioning
data will be executed.
When a control is skipped during interpolation control, the reference axis skip signal is turned ON. When the reference axis
skip signal is turned ON, a deceleration stop will be carried out for every axis, and the next reference axis positioning data
will be executed.
The M code ON signals will not turn ON when the M code output is set to the AFTER mode. (In this case, the M code will
not be stored in "[Md.25] Valid M code".)
The skip cannot be carried out by the speed control and position-speed switching control.
If the skip signal is turned ON with the M code signal turned ON, the transition to the next data is not carried out until the M
code signal is turned OFF.
Setting method from the CPU module
The following shows the settings and program example for skipping the control being executed in axis 1 with a command from
the CPU module.
Setting data
Set the following data.
n: Axis No. - 1
Refer to the following for the setting details.
Page 504 Control Data
Add the following program to the control program, and write it to the CPU module.
When the "skip command" is input, the value "1" (skip request) set in "[Cd.37] Skip command" is written to the buffer memory
of the Simple Motion module.
Program
Refer to the following for the program example.
Page 570 Skip program
Setting item Setting
value
Setting details Buffer memory address
[Cd.37] Skip command 1 Set "1: Skip request". 4347+100n

Table of Contents