EN-28
Maintenance
Cleaning the air ¿ lter
Cleaning
CAUTION
Do not clean the ¿ lters with boiling water.
Do not dry them over an open À ame.
Pull them out gently.
2
Before maintenance During the operational season
Remove the air ¿ lter
Reinstall the air ¿ lter
Hold ¿ rmly the ¿ lter at both sides as shown at
right and insert securely.
Close the air inlet panel.
Turn off the power supply.
2
3
How to open, close the air inlet panel
Open
Place ¿ ngers at the recesses on both sides of the panel and pull down
the panel forward so that it will be open by about 15 degrees.
Close
Push both ends evenly and press further lightly at the center.
Pull up the air inlet panel forward.
Lightly hold the knobs at both sides
and lift a little to remove the panel
forward.
If the ¿ lter is very dirty, clean it with warm
water (approx. 30 °C), and dry it thoroughly.
Removal
When removing the air inlet panel for internal cleaning or others, open the
panel, remove the string and then pull it forward.
Installation
Secure the upper edge of the air inlet panel by lightly pushing it in, place
the string as illustrated and then close the panel.
Do not use the following articles:
Hot water (40 °C or more)
It may deform or discolour the unit.
Petrol, paint thinner, benzine or cleanser, etc.
They may deform or scratch the unit.
Standard interval is once every two week
Do not spill any liquid.
Wipe the unit with a
soft, dry cloth.
There’s a danger
of electric shock.
Do not touch the aluminum ¿ ns on
the heat exchanger.
1
Removal, installation of air inlet panel
CAUTION
Make sure not to drop the air inlet panel.
CAUTION
Make sure not to drop the air inlet panel.
CAUTION
Operating without putting back the air ¿ lters
will make the unit dusty, and may cause
damage.
Cleaning the air inlet panel
Removal, installation of air inlet panel.
Wipe the unit with a soft, dry cloth, or use a
vacuum cleaner.
Cleaning the unit
Wipe the unit with a soft, dry cloth, or use a
vacuum cleaner.
If the unit is very dirty, wipe it with a cloth
soaked in warm water.
CAUTION
Do not wash the panel with water.
RFB012A009F_EN.indd 28 4/25/2020 9:30:16 PM