EasyManua.ls Logo

Mitsubishi A1SD75M3

Mitsubishi A1SD75M3
746 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 - 118
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
When " Pr.1 Unit setting" is "degree"
Da.2
setting value
Value set with peripheral device
(degree)
Value set with sequence program *
1
(
×
10
-5
degree)
ABS Linear 1 : 01
H
ABS Linear 2 : 04
H
Current value change : 11
H
Set the address
0 to 359.99999
Set the address
0 to 35999999
INC Linear 1 : 02
H
INC Linear 2 : 05
H
Fixed-dimension feed 1 : 03
H
Fixed-dimension feed 2 : 06
H
Set the movement amount
–21474.83648 to 21474.83647
Set the movement amount
–2147483648 to 2147483647
Forward run speed/position : 0F
H
Reverse run speed/position : 10
H
Set the movement amount
0 to 21474.83647
Set the movement amount
0 to 2147483647
Forward run Speed control : 0D
H
Reverse run Speed control : 0E
H
JUMP command : 12
H
(Setting not required) (Setting not required)
ABS Circular interpolation : 07
H
ABS Circular right : 09
H
ABS Circular left : 0A
H
INC Circular interpolation : 08
H
INC Circular right : 0B
H
INC Circular left : 0C
H
Circular interpolation control is not possible
When " Pr.1 Unit setting" is "pulse"
Da.2
setting value
Value set with peripheral device
(pulse)
Value set with sequence program *
1
(pulse)
ABS Linear 1 : 01
H
ABS Linear 2 : 04
H
Current value change : 11
H
Set the address
–2147483648 to 2147483647
Set the address
–2147483648 to 2147483647
INC Linear 1 : 02
H
INC Linear 2 : 05
H
Fixed-dimension feed 1 : 03
H
Fixed-dimension feed 2 : 06
H
Set the movement amount
–2147483648 to 2147483647
Set the movement amount
–2147483648 to 2147483647
Forward run speed/position : 0F
H
Reverse run speed/position : 10
H
Set the movement amount
0 to 2147483647
Set the movement amount
0 to 2147483647
Forward run Speed control : 0D
H
Reverse run Speed control : 0E
H
JUMP command : 20
H
(Setting not required) (Setting not required)
ABS Circular interpolation : 07
H
ABS Circular right : 09
H
ABS Circular left : 0A
H
Set the address
–2147483648 to 2147483647
Set the address
–2147483648 to 2147483647
INC Circular interpolation : 08
H
INC Circular right : 0B
H
INC Circular left : 0C
H
Set the movement amount
–2147483648 to 2147483647
Set the movement amount
–2147483648 to 2147483647

Related product manuals