5 - 174
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
5.7.2 Axis control data
Setting item Setting details
Cd.11
Positioning start No.
•
Set the positioning start No.
Cd.12
Axis error reset
•
Clears the axis error detection, axis error No., axis warning detection and axis
warning No.
•
When the AD75 axis operation state is "in error occurrence", the error is cleared
and the AD75 is returned to the "waiting" state.
Cd.13
Restart command
•
When positioning is stopped for any reason (when axis operation state is
"stopped"), set "1" in
Cd.13
. Positioning will be carried out again from the
stopped position to the end point of the stopped positioning data.
Cd.14
M code OFF request
•
The M code ON signal turns OFF.