5 - 179
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Storage buffer
memory address
Setting value Default value
Axis 1 Axis 2 Axis 3
Set with a decimal.
R
Unit conversion table
)
)
Cd.19
Example)
n
2
mm/min
3
inch/min
3
degree/min
0
pulse/s
Unit
Actual
value
×
10
n
Integer value
Setting value
(decimal)
When setting "20000.00mm/min" in the
" JOG speed", set "2000000" in
the buffer memory.
Cd.19
Cd.19
JOG speed
0
1160
1161
1210
1211
1260
1261
Set with a decimal.
K
Cd.20 Speed/position changeover enable flag
Setting value
0: Even if the speed/position changeover signal
turns ON, the control does not change from
speed to position control.
1: When the speed/position changeover signal
turns ON, the control changes from speed
to position control.
0 1163 1213 1263
Set with a decimal.
R
×
10
n
Unit conversion table
)
)
Cd.21
Example)
n
1
mm
5
inch
5
degree
0
pulse
Unit
Actual
value
Integer value
Setting value
(decimal)
When setting "20000.0mm" in the
" Speed/position changeover
control movement amount change
register", set "200000" in the buffer
memory.
Cd.21
Cd.21
Speed/position changeover control
movement amount change register
0
1164
1165
1214
1215
1264
1265

Related product manuals