1Error list
Error no. L4200
1-50
L4200 Error message Cannot write to file
Cause Write operation is prohibited, or the file capacity is insufficient.
Measures 1. Enable file writing.
2. Delete unnecessary files.
L4210 Error message Too long statement
Cause The command statement length is limited to 240 characters.
Measures Delete the No. of characters in the command statement to within 240 characters.
L4220 Error message Syntax error
Cause There is an error in the syntax of the input command statement.
Measures Re-input in the correct syntax after checking the contents.
L4230 Error message The line No. does not exist
Cause There is no specified line number.
Measures Check the contents, and reinput the correct line No.
L4240 Error message The statement is write protected
Cause The command statement is write protected.
Measures Cancel the write protection.
L4250 Error message No more lines or variables
Cause Reading of lines and variables exceeding the registered ones.
Measures Check the programs.
L4300 One of the errors below is detected.
Please take measures corresponding to an error message.
Error message Too long variable name
Cause The variable name length is limited to 16 characters
Measures Shorten the variable name to within 16 characters
Error message Too long variable/function name
Cause The variable/function name length is limited to 32 characters.
Measures Shorten the variable/function name to within 32 characters.
L4310 Error message Illegal character is used
Cause A character other than A to Z or 0 to 9 was used.
Measures Use the character which can be used.
L4320 Error message The variable is write protected
Cause The variable is write protected.
Measures 1. Use a writable variable.
2. Cancel the write protection.
L4330 Error message The variable is read protected
Cause The variable is read protected.
Measures 1. Use a writable variable.
2. Cancel the write protection.
L4340 Error message The variable is not defined
Cause The variable has not been defined.
Measures Define the variable.
L4341 Error message The user external variable is not defined.
Cause The user external variable has not been defined
Measures Define the user external variable
L4350 Error message Duplicate definition (Val.)
Cause Variables already defined cannot be redefined with the Dim or Def statements.
Measures 1. Change the variable name and define.
2. Delete the defined variable.
L4360 Error message Same variable used (65535 times)
Cause Example: 1 P1=P1+P2 references P1 twice and P2 once.
Measures Change the program to reduce the No. of times the same variable is used.
Error No. Error cause and measures

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi CR800 Series and is the answer not in the manual?

Mitsubishi CR800 Series Specifications

General IconGeneral
BrandMitsubishi
ModelCR800 Series
CategoryController
LanguageEnglish

Related product manuals