EasyManua.ls Logo

Mitsubishi D700 VFD User Manual

Mitsubishi D700 VFD
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
MachMotion Version 1.0.2
MACHMOTION
Mitsubishi D700 VFD
Installation Guide
3/12/2012
Everything you need to know to
set
up your Mitsubishi VFD.
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi D700 VFD and is the answer not in the manual?

Mitsubishi D700 VFD Specifications

General IconGeneral
Output Frequency0.2 to 400 Hz
Overload Capacity150% for 60 seconds
CommunicationRS-485
Braking UnitBuilt-in
Input Frequency50/60 Hz
Rated Output CurrentVaries by model
Cooling MethodFan Cooled
Humidity95% RH or less (non-condensing)
Enclosure RatingIP20
WeightVaries by model
Input Voltage200-240V
Control MethodV/F Control
Protection FeaturesOvercurrent, overvoltage, overheating
Operating Temperature-10°C to +50°C
Output Voltage0-Input Voltage
Power RatingVaries by model
Storage Temperature-20°C to +65°C
AltitudeUp to 1000 m

Summary

Overview

Wiring and Connections

Control Cable Wiring

Explains the Cat5 control cable connection between the breakout board and the VFD, detailing wire color to VFD connection.

Enable Circuit Setup

Spindle Motor and Brake Resistor

Spindle Motor Connection

Instructions on connecting the spindle motor wires to the VFD terminals (U, V, W) and how to reverse direction.

Brake Resistor Selection and Connection

Information on selecting and connecting a brake resistor based on motor HP, including a table and connection diagram.

VFD Configuration and Tuning

VFD Programming and User Interface

Guide to navigating the VFD user interface and the procedure for setting parameters in PU mode.

VFD Setup Parameters

Lists parameters that should not be changed and those that may require adjustment based on motor specifications.

VFD Auto Tuning

Instructions for performing auto-tuning on the VFD, especially if the spindle is not working well.

VFD Test Run

Step-by-step guide to testing the spindle motor directly from the VFD using the interface.

Mach3 Integration and Operation

Mach3 Spindle Setup and Pulley Configuration

Explains how to configure Mach3 by setting spindle RPM and pulleys to match the VFD's analog output.

Mach3 Control via Macros and Outputs

Describes using M-codes (M41-M45) and outputs (12-16) for changing pulleys or gears within Mach3.

Setting Spindle Speed in Mach3

Instructions on setting the spindle speed in Mach3 and initiating the spindle operation.

Manual and M-Code Spindle Control

Explains manual control via FWD/REV buttons and programmatic control using M-codes (M3, M4, M5).

Calibrating Your Spindle

Calibration with Spindle Feedback

Method for calibrating spindle speed using a tachometer or feedback, involving calculating a new velocity value.

Calibration without Spindle Feedback

Method for calibrating spindle speed without feedback, using VFD frequency and Mach3 pulley settings.

Troubleshooting and Diagnostics

Spindle Not Turning On Troubleshooting

Provides a step-by-step guide for diagnosing and resolving issues when the spindle is not turning on.

VFD Alarm, Error, and Fault Codes

Lists VFD error messages, warnings, and fault codes, their descriptions, and corrective actions.

Warranty Information

Related product manuals