PARAMETERS
123
<Computer programming>
(
1
)
Communication protocol
Data communication between the computer and inverter is performed using the
following procedure:
Data read
Data write
1) 5)4)
3)
2)
*
1
*
2
↓
(Data flow)
Inverter
Inverter
Time
Computer
Computer
↓
(Data flow)
*1. If a data error is detected and a retry must be made, execute retry operation with
the user program. The inverter comes to an alarm stop if the number of consecutive
retries exceeds the parameter setting.
*2. On receipt of a data error occurrence, the inverter returns "reply data 3" to the
computer again. The inverter comes to an alarm stop if the number of consecutive
data errors reaches or exceeds the parameter setting.
(
2
)
Communication operation presence/absence and data format types
Communication operation presence/absence and data format types are as follows:
No. Operation
Run
Command
Running
Frequency
Parameter
Write
Inverter
Reset
Monitor-
ing
Parame-
ter Read
1)
Communication request is
sent to the inverter in
accordance with the user
program in the computer.
A'
A
(A")
Note1
A
(A")
Note2
ABB
2)
Inverter data processin
time
Present Present Present Absent Present Present
No error*
Request
accepted)
C C C Absent
E, E'
(E")
Note1
E
(E")
Note2
3)
Reply data
from the
inverter
(Data 1) is
checked for
error.
With error
request
rejected)
D D D Absent F F
4)
Computer processin
dela
time
Absent Absent Absent Absent Absent Absent
No error*
No inverter
processing
Absent Absent Absent Absent G G
5)
Answer from
computer in
res
onse to re
l
data 3. (Data 3 is
checked for
error)
With error.
Inverter
outputs 3)
again
Absent Absent Absent Absent H H
* In the communication request data from the computer to the inverter, 10ms or more is
also required after "no data error (ACK)". (Refer to page 126.)
Note:1 Setting any of "0.01 to 9998" in Pr. 37 "speed display" and "1" in data code
"HFF" changes the data format to A" or E" (400V class). Regardless of the data
code "HFF" setting, the data format for 200V or 100V class is always A" or E".
The output frequency is the value of the speed display and its unit is
0.001r/min. If the data code FF is not 1, the unit is 1r/min and the 4-digit data
format can be used.
2 The read/write data format of Pr. 37 "speed display" is always E"/A".