PROTECTIVE FUNCTIONS
174
5.1.2 To know the operating status at the occurrence of alarm
When any alarm has occurred, the display automatically switches to the indication of
the corresponding protective function (error). By pressing the
MODE
key at this point
without resetting the inverter, the display shows the output frequency. In this way, it is
possible to know the running frequency at the occurrence of the alarm. This also
applies to the current. After resetting, you can confirm the data in the alarm history
(refer to page 56).
5.1.3 Correspondence between digital and actual characters
There are the following correspondences between the actual alphanumeric characters
and the digital characters displayed on the control panel (FR-PA02
-02
):
Actual Display Actual Display Actual Display
0
1
2
3
4
5
6
7
8
9
B
C
D
E
F
G
H
I
J
L
A
N
O
P
T
U
V
r
-
M
o
S
5.1.4 Resetting the inverter
The inverter can be reset by performing any of the following operations. Note that the
electronic overcurrent protection's internal heat calculation value and the number of
retries are cleared (erased) by resetting the inverter.
Operation 1: ...... Using the control panel (FR-PA02
-02
), press the
STOP
RESET
key to reset the
inverter. (This may only be performed when the inverter protective
function (major fault) is activated.)
Operation 2: ...... Switch power off once, then switch it on again.
Operation 3: ...... Switch on the reset signal (RES).