PARAMETERS
131
No.
Item
Instruction
Code
Description
Number
of Data
Digits
(Data
code
FF=1)
Read H7F
11
Link
parameter
expansion
setting
Write HFF
H00 to H6C and H80 to HEC parameter values
are changed.
H00: Pr. 0 to Pr. 96 values are accessible.
H01: Pr. 117 to Pr. 158 and Pr. 900 to Pr. 905
values are accessible.
H02: Pr. 160 to Pr. 192 and Pr. 232 to Pr. 251
values are accessible.
H03: Pr. 338 to Pr. 340 values are accessible.
(only 400V class fitted with FR-E5NC),
Pr. 342 value is accessible (400V class
only)
H09: Pr. 990, Pr. 991 value is accessible.
2 digits
Read H6C
12
Second
parameter
changing
(Code HFF=1)
Write HEC
When setting the bias/gain (data codes H5E to
H6A, HDE to HED) parameters
H00: Offset/gain
H01: Analog
H02: Analog value of terminal
2 digits
REMARKS
For the instruction codes HFF, HEC, their set values are held once the
y
are written,
but changed to 0 when the inverter is reset or all clear is performed.

Table of Contents