204
Data Code
Func-
tion
Parameter
Number
Name
Read Write
Link Parameter Extension
Setting
(Data Code 7F/FF)
117
Station number 11 91 1
118
Communication speed 12 92 1
119
Stop bit length 13 93 1
120
Parity check presence/absence 14 94 1
121
Number of communication retries 15 95 1
122
Communication check time
interval
16 96 1
123
Waiting time setting 17 97 1
Communication
functions
124
CR
⋅
LF presence/absence
selection
18 98 1
128
PID action selection 1C 9C 1
129
PID proportional band 1D 9D 1
130
PID integral time 1E 9E 1
131
Upper limit 1F 9F 1
132
Lower limit 20 A0 1
133
PID action set point for PU
operation
21 A1 1
PID control
134
PID differential time 22 A2 1
145
Parameter unit language switch
over
2D AD 2
Additional
function
146
Parameter set by manufacture. Do not set.
150
Output current detection level 32 B2 1
151
Output current detection period 33 B3 1
152
Zero current detection level 34 B4 1
Current
detection
153
Zero current detection period 35 B5 1
156
Stall prevention operation
selection
38 B8 1
Sub
function
158
AM terminal function selection 3A BA 1
Additional
function
160
User group read selection
00 80 2
Initial
monitor
171
Actual operation hour meter clear 0B 8B 2
173
User group 1 registration 0D 8D 2
174
User group 1 deletion 0E 8E 2
175
User group 2 registration 0F 8F 2
User
functions
176
User group 2 deletion 10 90 2
180
RL terminal function selection 14 94 2
181
RM terminal function selection 15 95 2
182
RH terminal function selection 16 96 2
183
MRS terminal function selection 17 97 2
190
RUN terminal function selection 1E 9E 2
191
FU terminal function selection 1F 9F 2
Terminal
assignment functions
192
A, B, C terminal function selection
20 A0
2