Inspection item
100
PRECAUTIONS FOR MAINTENANCE AND INSPECTION
Removal of the internal fan (FR-F846-00250(11K) to 00470(22K))
(1) Remove the inverter front cover. (Refer to page 18)
(2) Remove the installation screws, and then remove the protective cover.
(3) Move the fan connector case, and then remove the fan connector.
(4) Remove the bracket.
(5) Remove the installation screws, and then remove the fan.
Installation screw
Protective cover
Fan connector
Connector case
Bracket
Bracket
Fan
Installation screw