EasyManua.ls Logo

Mitsubishi FR-F800-E - Page 107

Mitsubishi FR-F800-E
143 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inspection item
106
PRECAUTIONS FOR MAINTENANCE AND INSPECTION
Reinstallation of the internal fan (FR-F846-00620(30K) to 01160(55K))
(1) Fix the fan to the inverter with the bracket and the installation screws. (tightening torque 1.4 to 1.9 N•m)
After confirming the orientation of the fan, reinstall the fan so that air flows as shown below.
(The "AIR FLOW" arrow on the fan side indicates the air flow direction.)
(2) Reconnect the fan connector, and then place the connector case from the above.
(3) Reinstall the inverter front cover. (Refer to page 18.)
NOTE
Installing the fan in the opposite direction of air flow can cause the inverter life to be shorter.
Prevent the cable from being caught when installing a fan.
AIR FLOW
<Fan side>
Installation screw
Bracket
Fan
Fan Inverter
Bracket
Installation screw
View of fan side and surrounding
Air flow
direction
Fan connector
Connector case

Table of Contents

Related product manuals