Connection of stand-alone option units
62
INSTALLATION AND WIRING
2.9.5 Connection of the multifunction regeneration
converter (FR-XC)
Common bus regeneration mode with harmonic suppression disabled
(Pr.416 = "0")
When connecting the multifunction regeneration converter (FR-XC) to improve the braking capability, perform wiring securely
as follows. Incorrect connection will damage the converter and the inverter.
Turn ON switch 1 (connection mode setting switch) in the function selection switch assembly (SW2). If the switch setting does
not match the actual wiring, the connection mode fault "E.T" occurs.
After making sure that the wiring is correct and secure, set "2 or 102" in Pr.30 Regenerative function selection.