FX
3G
/FX
3U
/FX
3UC
 PLC User's Manual - Positioning Control Edition
Built-in Positioning Functions
8 1-Speed Positioning - DRVI/DRVA Instruction
8.3 Drive To Absolute - DRVA Instruction
B - 120
The rotation direction ON/OFF status of the specified device is shown in the following table.
During instruction execution, however, do not use the output    for other purposes.
8.3.4 Important Points
→ For the important points of programming, refer to Section 4.7.
• If an the operand is changed during instruction execution, the change will be ignored and the operation will 
not be affected.
Note that the changed operand will be enabled at the next activation of the instruction.
• If the instruction activation contact is turned off during execution of the instruction, the speed will 
decelerate and the operation will stop.
In this case, the "Instruction execution complete" flag (M8029) will not be turned on.
• If the limit flag (forward limit relay or reverse limit relay) in the operation direction is turned on, the speed 
will decelerate and the operation will stop.  In this case, the "Instruction execution abnormal end" flag 
(M8329) will be turned on when execution of the instruction is complete.
→ For details on the "Instruction execution abnormal end" flag, refer to Subsection 4.7.4.
• If the "pulse output monitor" (BUSY/READY) flag is on, a positioning instruction (including PLSR and 
PLSY) that uses the same output cannot be executed.
If the "pulse output monitor" (BUSY/READY) flag is still on after the instruction activation contact is turned 
off, do not execute a positioning instruction (including PLSR and PLSY instructions) that uses the same 
output number.
ON/OFF status of device 
specified by 
Rotation direction (increase/decrease current value)
ON
Forward rotation (Outputting pules from 
  will 
increase the current value.)
The rotation direction (normal or reverse 
rotation) depends on which value is larger; 
the number of output pulses specified by 
 (absolute address) or the value 
indicated in the current value register.
OFF
Reverse rotation (Outputting pules from   will 
reduce the current value.)
 
D
2
 
D
2
 
D
1
  S
 
D
1