Transition from MELSEC FX3U, FX3UC Series to
MELSEC iQ-F Series Handbook
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC FX3U Series and is the answer not in the manual?

Mitsubishi MELSEC FX3U Series Specifications

General IconGeneral
SeriesMELSEC FX3U
Program Memory64k steps
TypePLC (Programmable Logic Controller)
I/O CapacityUp to 384 points (with expansion)
Programming LanguageFunction Block Diagram
Communication ProtocolsRS-422, RS-485
Power Supply24 VDC or 100-240 VAC
Execution Speed0.065 μs per basic instruction
Built-in FunctionsPID control
Built-in Communication PortsRS-422
Expansion Modulescommunication modules
High-speed CountersUp to 6 channels, up to 100 kHz
Pulse OutputUp to 100 kHz
Operating Temperature0°C to 55°C

Summary

SAFETY PRECAUTIONS

DESIGN PRECAUTIONS

Guidelines for designing safe PLC systems, including emergency stops and interlocks.

INSTALLATION PRECAUTIONS

Instructions for safe installation, including power cutoff and environmental considerations.

WIRING PRECAUTIONS

Safety measures for wiring, including power supply, terminal blocks, and grounding.

STARTUP AND MAINTENANCE PRECAUTIONS

Precautions for safe startup, operation modification, and maintenance of the PLC.

OPERATION PRECAUTIONS

Guidelines for safe operation, including interlock circuits and program changes.

DISPOSAL PRECAUTIONS

Procedures for environmentally safe recycling and disposal of the PLC and batteries.

TRANSPORTATION PRECAUTIONS

Safety measures to prevent damage and ensure stability during PLC transportation.

INTRODUCTION

RELEVANT MANUALS

TERMS

1.1 Outline of the MELSEC iQ-F Series

1.2 Substitute Models

Selection and Replacement of the Models

Steps and considerations for selecting and replacing FX3 models with iQ-F series.

Replacement of the Projects

Method for converting FX3U/FX3UC projects to MELSEC iQ-F projects using GX Works3.

2 Replacement from FX3 U to FX5 U

2.1 Outline

Introduction to the FX5U as a successor to the FX3U, detailing its capabilities.

2.2 Replacement Procedure

Step-by-step guide for replacing FX3U PLCs with FX5U successor models.

2.3 Selection of Substitute Models

Recommended substitute models for FX3U CPU modules and extension devices.

2.4 Conversion of the Projects

Guidance on converting existing FX3U/FX3UC projects for use with MELSEC iQ-F.

2.5 Replacement of the PLC

Key considerations for physically replacing the FX3U PLC with its successor.

3 Replacement from FX3 UC to FX5 UC

3.1 Outline

Introduction to the FX5UC as a successor to the FX3UC, emphasizing its compact design.

3.2 Replacement Procedure

Step-by-step guide for replacing FX3UC PLCs with FX5UC successor models.

3.3 Selection of Substitute Models

Recommended substitute models for FX3UC CPU modules and extension devices.

3.4 Conversion of the Projects

Guidance on converting existing FX3UC projects for use with MELSEC iQ-F.

3.5 Replacement of the PLC

Key considerations for physically replacing the FX3UC PLC with its successor.

4 Conversion of the Projects

4.1 Operation Method for Replacing Projects

Detailed procedure for converting FX3U/FX3UC projects to MELSEC iQ-F using GX Works3.

4.2 Precautions when Converting the Projects

Important precautions and potential issues when converting FX3 projects to MELSEC iQ-F.

4.3 Precautions when Replacing the Parameters

Guidance on resetting and reconfiguring parameters after project conversion.

4.4 Precautions when Replacing Other Functions

Specific precautions for functions like high-speed counters and routine timers during conversion.

Related product manuals