E-112
FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
12 Related Data
12.5 FREQROL Inverter Parameter List
12.5 FREQROL Inverter Parameter List
This section shows the list of parameters provided in FREQROL F700, A700, E700, V500, F500, A500, E500
and S500 Series inverters.
For details on each function, refer to the respective inverter manual.
12.5.1 Parameters in V500, F500, A500, E500, and S500 Series
The following parameters are provided in FREQROL inverters. (For details, make sure to refer to the
respective inverter manual.)
FREQROL V500 Series FREQROL F500 Series FREQROL A500 Series FREQROL E500 Series FREQROL S500 Series
Function
Pr 
No.
Name
Pr 
No.
Name
Pr 
No.
Name
Pr 
No.
Name
Pr 
No.
Name
Basic
functions
0
Torque boost 
(manual)
0 Torque boost 0
Torque boost
*3
0
Torque boost
*3
0
Torque boost
*3
1
Maximum speed 
(simple mode)
1
Maximum 
frequency
1
Maximum 
frequency
1
Maximum 
frequency
1
Maximum 
frequency
2
Minimum speed 
(simple mode)
2
Minimum 
frequency 
2
Minimum 
frequency 
2
Minimum 
frequency 
2
Minimum 
frequency 
3 Base frequency 3 Base frequency 3 Base frequency 3
Base frequency
*3
3
Base frequency
*3
4
Multi-speed 
setting 
(high speed) 
(simple mode)
4
Multi-speed 
setting 
(high speed) 
4
Multi-speed 
setting 
(high speed) 
4
Multi-speed 
setting 
(high speed) 
4
Multi-speed 
setting 
(high speed) 
5
Multi-speed 
setting 
(middle speed)
(simple mode)
5
Multi-speed 
setting 
(middle speed)
5
Multi-speed 
setting 
(middle speed)
5
Multi-speed 
setting 
(middle speed)
5
Multi-speed 
setting 
(middle speed)
6
Multi-speed 
setting 
(low speed) 
(simple mode)
6
Multi-speed 
setting 
(low speed)
6
Multi-speed 
setting 
(low speed)
6
Multi-speed 
setting 
(low speed)
6
Multi-speed 
setting 
(low speed)
7
Acceleration time 
(simple mode)
7 Acceleration time 7 Acceleration time 7 Acceleration time 7 Acceleration time
8
Deceleration time 
(simple mode)
8 Deceleration time 8 Deceleration time 8 Deceleration time 8 Deceleration time
9
Electronic thermal 
O/L relay
9
Electronic thermal 
O/L relay
9
Electronic thermal 
O/L relay
9
Electronic thermal 
O/L relay
9
Electronic thermal 
O/L relay
Standard
operation
functions
10
DC injection brake 
operation speed
10
DC injection brake 
operation 
frequency
10
DC injection brake 
operation 
frequency
10
DC injection brake 
operation 
frequency
10
DC injection brake 
operation 
frequency
11
DC injection brake 
operation time
11
DC injection brake 
operation time
11
DC injection brake 
operation time
11
DC injection brake 
operation time
11
DC injection brake 
operation time
12
DC injection brake 
voltage
12
DC injection brake 
voltage
12
DC injection brake 
voltage
12
DC injection brake 
voltage
12
DC injection brake 
voltage
13 Starting speed 13 Starting frequency 13 Starting frequency 13 Starting frequency 13 Starting frequency
⎯⎯14
Load pattern 
selection
14
Load pattern 
selection
*3
14
Load pattern 
selection
*3
14
Load pattern 
selection
*3
15 Jog speed setting 15 Jog frequency 15 Jog frequency 15 Jog frequency 15 Jog frequency
16
Jog acceleration/
deceleration time
16
Jog acceleration/
deceleration time
16
Jog acceleration/
deceleration time
16
Jog acceleration/
deceleration time
16
Jog acceleration/
deceleration time
Standard
operation
function
(V500
Series
operation
selection
functions)
17
MRS input 
selection
17
MRS input 
selection
17
MRS input 
selection
⎯⎯17
RUN key rotation 
direction selection
⎯⎯⎯⎯18
High speed 
maximum 
frequency
18
High speed 
maximum 
frequency
⎯⎯
19
Base frequency 
voltage
19
Base frequency 
voltage
19
Base frequency 
voltage
*3
19
Base frequency 
voltage
*3
19
Base frequency 
voltage
*3