USER'S MANUAL - Data Communication Edition
FX SERIES PROGRAMMABLE CONTROLLERS
N:N Network
Parallel Link
Computer Link
Inverter Communication
Non-Protocol Communication
Programming Communication
Remote Maintenance
FX
3U
Series
Inverter Communication
(F700/A700/E700/D700 Series)
FX
3G
Series
EFX3UƒVƒŠ[ƒY
Additional Product Support
Version
FX
3U
-232-BD
RS-232C Interface
FX
2N
-232-BD
FX
1N
-232-BD
FX
3U
-232ADP(-MB)
FX-232ADP
FX
2NC
-232ADP
FX
0N
-232ADP
FX
2N
-232IF
RS-485 Interface
FX
3U
-485-BD
FX
2N
-485-BD
FX
1N
-485-BD
FX
3U
-485ADP(-MB)
FX-485ADP
FX
2NC
-485ADP
FX
0N
-485ADP
RS-485/232C Converter
FX-485PC-IF
FX
3U
-422-BD
FX
1N
-422-BD
FX
2N
-422-BD
RS-422 Interface
USB Interface
FX
3U
-USB-BD
FX
3G
-232-BD
FX
3G
-485-BD
FX
3G
-422-BD

Table of Contents

Questions and Answers

  • J
    Joseph HartAug 14, 2025
    Should I set parameters for the N:N Network on my Mitsubishi Controller?
    • M
      Mindy NguyenAug 14, 2025
      No, you should not set parameters for the N:N Network. Verify that the communication settings using parameters are suitable for use.
  • C
    Christopher AllenAug 17, 2025
    What to do if communication is not possible with Mitsubishi Controller because of incorrect wiring?
    • A
      Ana FoxAug 17, 2025
      If communication is failing, it might be due to incorrect wiring. Ensure that all communication equipment is wired correctly.
  • S
    Sherri LynnAug 21, 2025
    What to do if communication is not possible with Mitsubishi FX3U-USB-BD when a communication port is set twice?
    • O
      Olivia JohnsonAug 21, 2025
      If communication fails, it could be because a communication port is set more than once. Verify that the communication format (D8120, D8400 and D8420) is set correctly.
  • L
    Leslie TaylorAug 26, 2025
    What to do if communication is not possible with Mitsubishi FX3U-USB-BD when using RS and RS2 instructions?
    • M
      marystoneAug 26, 2025
      If communication is failing, check that the RS and RS2 instructions are not being used for the same channel.
  • M
    Mary WilsonAug 28, 2025
    What to do if communication is not possible with Mitsubishi FX3U-USB-BD Controller when using the RS instruction?
    • C
      Christian MeyerAug 29, 2025
      If communication is not working, verify that the RS instruction is not used in the program.
  • L
    Linda ManningSep 1, 2025
    What to do if communication is not possible with Mitsubishi Controller when using EXTR instruction?
    • M
      melaniepierceSep 1, 2025
      If communication isn't working, ensure that the EXTR instruction is not used in the program.
  • J
    Joseph PowellSep 5, 2025
    What to do if communication is not possible with Mitsubishi Controller when using VRRD and VRSC instructions?
    • Q
      qbennettSep 5, 2025
      If communication isn't working, verify that the VRRD and VRSC instructions are not used in the program.
  • A
    amandawilliamsSep 9, 2025
    What to do if communication is not possible with Mitsubishi Controller when using IVCK, IVDR, IVRD, IVWR, and IVBWR instructions?
    • J
      Jessica HolmesSep 9, 2025
      If communication is failing, verify that the IVCK, IVDR, IVRD, IVWR and IVBWR instructions are not being used for the same channel.

Mitsubishi FX3U-USB-BD Specifications

General IconGeneral
InterfaceUSB
USB StandardUSB 2.0
Communication SpeedUp to 12 Mbps
CompatibilityMitsubishi FX3U Series PLC
FunctionalityProgramming and communication with FX3U PLC
InstallationEasy installation on FX3U PLC
Power SupplyPowered by PLC