Should I set parameters for the N:N Network on my Mitsubishi Controller?
- CCassandra ReynoldsAug 14, 2025
No, you should not set parameters for the N:N Network. Verify that the communication settings using parameters are suitable for use.
Should I set parameters for the N:N Network on my Mitsubishi Controller?
No, you should not set parameters for the N:N Network. Verify that the communication settings using parameters are suitable for use.
What to do if communication is not possible with Mitsubishi FX3U-422-BD Controller because of incorrect wiring?
If communication is failing, it might be due to incorrect wiring. Ensure that all communication equipment is wired correctly.
What to do if communication is not possible with Mitsubishi FX3U-422-BD when a communication port is set twice?
If communication fails, it could be because a communication port is set more than once. Verify that the communication format (D8120, D8400 and D8420) is set correctly.
What to do if communication is not possible with Mitsubishi FX3U-422-BD Controller when using RS and RS2 instructions?
If communication is failing, check that the RS and RS2 instructions are not being used for the same channel.
What to do if communication is not possible with Mitsubishi FX3U-422-BD Controller when using the RS instruction?
If communication is not working, verify that the RS instruction is not used in the program.
What to do if communication is not possible with Mitsubishi Controller when using EXTR instruction?
If communication isn't working, ensure that the EXTR instruction is not used in the program.
What to do if communication is not possible with Mitsubishi FX3U-422-BD Controller when using VRRD and VRSC instructions?
If communication isn't working, verify that the VRRD and VRSC instructions are not used in the program.
What to do if communication is not possible with Mitsubishi Controller when using IVCK, IVDR, IVRD, IVWR, and IVBWR instructions?
If communication is failing, verify that the IVCK, IVDR, IVRD, IVWR and IVBWR instructions are not being used for the same channel.
Category | Controller |
---|---|
Model | FX3U-422-BD |
Communication Protocol/Interface/Standard | RS-422 |
Function | Serial communication |
Channels | 1 |
Current Consumption | 50 mA |
Compatibility | Mitsubishi FX3U series |
Power Supply | 5V DC (from PLC) |
Guidelines for designing safe systems by implementing external safety circuits and considering PLC failure scenarios.
Safety measures during wiring, including power disconnection, proper cable management, and noise prevention.
Precautions for operation, terminal cleaning, and program modifications to prevent electric shock and malfunctions.
Overviews the various communication types supported by FX PLCs, including serial communication and link types.
Details the systems, applications, and functions of different communication types like CC-Link, N:N Network, Parallel Link, Computer Link, etc.
Explains communication types supported by serial ports and network connectors, and references system configuration.
Describes which communication parameters can be changed for each communication type and provides methods on how to change them.
Specifies the manuals related to PLC main units for each communication type.
Lists abbreviations, generic names, and terms used throughout the manual for clarity.