50
4 Conversion of the Projects
4.4 Precautions when Replacing Other Functions
2. Set the function of the high-speed counters used at FX3U/FX3UC.
Select the input comparison enable/disable of the counter device and preset input compatible with the FX3 Series, and select
the control switch.
Changing the Program
Change the high-speed counter program by referring to the following program example.
[Example of program]
M0
LC35
Y001
UDCNTF LC35 K10000
M0
C235
Y001
C235
K10000
Change to