5.1 Type Conversion Functions
5.1.29 String type
single-precision real type conversion
5-89
5
APPLICATION
FUNCTIONS
STR_TO_REAL(_E)
STR_TO_REAL(_E)
(2) Both string type data in decimal point form and exponent form can be converted to single-
precision real type data.
(a) Decimal point form
(b) Exponent form
(3) As the number of significant figures of string type data is 6, the 7th and later digits excluding
the sign, decimal point, and exponent part are cut and converted.
(a) Decimal point form
(b) Exponent form
(4) When a sign is not specified or '2B
H' (+) is specified for a sign in decimal point form, string
type data is converted as a positive value. When '2D
H' () is specified for a sign, string type
data is converted as a negative value.
(5) When a sign is not specified or '2B
H' (+) is specified for a sign of the exponential part in
exponent form, string type data is converted as a positive value.
When '2D
H' () is specified for a sign of the exponential part, string type data is converted as
a negative value.
Single-precision real type
33H(3) 2EH(.)
30
H(0)35H(5)
34
H(4)33H(3)
00
H
31H(1) 2DH(-)
2nd word
3rd word
4th word
5th word
String 1st word
High-order byte Low-order byte
-1.35034
3053.1-4
Single-precision real type
33H(3) 2EH(.)
30
H(0)35H(5)
34
H(4)33H(3)
2D
H(-) 45H(E)
30
H(0)31H(1)
00
H
31H(1) 2DH(-)
2nd word
3rd word
4th word
5th word
6th word
7th word
String 1st word
High-order byte Low-order byte
-1.35034E-10
E43053.1--1 0
Single-precision real type
-1.35034
Cut
30531- 4120 2 3
.
Single-precision real type
-1.35034E-10
Cut
3053.1-412E-1 0

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
SeriesMELSEC Q Series
TypeModular PLC
Programming SoftwareGX Works2, GX Works3
CategoryProgrammable Logic Controller (PLC)
I/O ModulesDigital I/O, Analog I/O, High-Speed Counter, Positioning
CommunicationEthernet, CC-Link
Programming LanguagesLadder Logic, Structured Text, Function Block Diagram, Sequential Function Chart, Instruction List
MemoryFlash Memory
I/O PointsUp to 4096 points (expandable with additional modules)
Power SupplyAC or DC power supply options available, depending on the base unit and modules.
MountingDIN rail mounting
Operating Temperature0°C to 55°C
Storage Temperature-25°C to 75°C
Humidity5% to 95% (non-condensing)
Vibration Resistance10 to 57 Hz, 0.075mm amplitude
WeightVaries depending on the module, from a few grams to several kilograms.
Shock Resistance147 m/s² (3 times each in X, Y, Z directions)