5.1 Type Conversion Functions
5.1.35 Time type
bit type conversion
5-107
5
APPLICATION
FUNCTIONS
TIME_TO_BOOL(_E)
TIME_TO_BOOL(_E)
5.1.35 Time type bit type conversion
TIME_TO_BOOL(_E)
Function
Operation processing
Converts time type data input to into bit type data, and outputs the operation result from
.
When the input value is 0ms, FALSE is output in bit type data.
When the input value is other than 0ms, TRUE is output in bit type data.
TIME_TO_BOOL(_E)
_E: With EN/ENO
indicates any of the following
functions.
TIME_TO_BOOL TIME_TO_BOOL_E
Input argument, EN:
Executing condition (TRUE: Execution, FALSE: Stop) :Bit
s:
Input :Time
Output argument, ENO:
Output status (TRUE: Normal, FALSE: Error) :Bit
d:
Output :Bit
Universal
UD
High
Performance
EN ENO
ds
TIME_TO_BOOL_E
(EN, s, d);ENO:=
Structured ladder
ST
TIME_TO_BOOL_E
s
d
Time type
20m34s567ms
0ms
Bit
type
TRUE
FALSE

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC Q Series and is the answer not in the manual?

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC Q Series
CategoryController
LanguageEnglish

Related product manuals