5-160
5.7 Standard Character String Functions
5.7.2 String concatenation
CONCAT(_E)
5.7.2 String concatenation
CONCAT(_E)
Function
Operation processing
(1) Concatenates the character string input to following the one input to , and outputs the
operation result from .
This function concatenates character string with ignoring '00
H', which indicates the end of
character string .
If the concatenated character string has over 255 bytes, the character string up to 255 bytes
is output.
(2) The values to be input to and are string type data within the range from 0 to 255
bytes.
CONCAT(_E)
_E: With EN/ENO
indicates any of the following
functions.
CONCAT CONCAT_E
Input argument, EN:
Executing condition (TRUE: Execution, FALSE: Stop) :Bit
s1:
Input :String
s2:
Output argument, ENO:
Output status (TRUE: Normal, FALSE: Error) :Bit
d:
Output :String
Universal
UD
High
Performance
Structured ladder
EN ENO
ds1
s2
ST
(EN, s1, s2, d);ENO:=
CONCAR_E
CONCAT_E
s2
s1
d
s2
s1
32H(2) 31H(1)
34
H(4)33H(3)
36
H(6)
00
H
35H(5)
'123456'
42H(B) 41H(A)
44
H(D) 43H(C)
31
H(1) 45H(E)
33
H(3) 32H(2)
35
H(5) 34H(4)
00
H 36H(6)
42
H(B) 41H(A)
44
H(D) 43H(C)
00
H 45H(E)
'ABCDE' 'ABCDE123456'
2nd word
3rd word
1st word
2nd word
3rd word
4th word
1st word
2nd word
3rd word
4th word
5th word
6th word
1st word
High-order byte Low-order byte High-order byte Low-order byte High-order byte Low-order byte
+
s1
s2

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
SeriesMELSEC Q Series
TypeModular PLC
Programming SoftwareGX Works2, GX Works3
CategoryProgrammable Logic Controller (PLC)
I/O ModulesDigital I/O, Analog I/O, High-Speed Counter, Positioning
CommunicationEthernet, CC-Link
Programming LanguagesLadder Logic, Structured Text, Function Block Diagram, Sequential Function Chart, Instruction List
MemoryFlash Memory
I/O PointsUp to 4096 points (expandable with additional modules)
Power SupplyAC or DC power supply options available, depending on the base unit and modules.
MountingDIN rail mounting
Operating Temperature0°C to 55°C
Storage Temperature-25°C to 75°C
Humidity5% to 95% (non-condensing)
Vibration Resistance10 to 57 Hz, 0.075mm amplitude
WeightVaries depending on the module, from a few grams to several kilograms.
Shock Resistance147 m/s² (3 times each in X, Y, Z directions)