5.7 Standard Character String Functions
5.7.4 String deletion
5-167
5
APPLICATION
FUNCTIONS
DELETE(_E)
DELETE(_E)
(Example) Values input to and are 5
(2) The value to be input to is string type data within the range from 0 to 255 bytes.
(3) The value to be input to is word (signed) type data within the range from 0 to 255.
(The input value must not exceed the number of characters of character string input to .)
(4) The value to be input to is word (signed) type data within the range from 1 to 255.
(The input value must not exceed the number of characters of character string input to .)
Operation result
(1) Function without EN/ENO
An operation is executed and the operation value is output from .
(2) Function with EN/ENO
The following table shows the executing conditions and operation results.
*1 When FALSE is output from ENO, the data output from is undefined.
In this case, create a program so that the data output from is not used.
EN ENO
TRUE (Operation execution) TRUE Operation output value
FALSE (Operation stop)
FALSE
*1
Undefined value
n1
n2
Number of characters to be deleted : 5 characters
Start position to
be deleted :
5th character
'ABCD45'
42
H(B) 41H(A)
44
H(D) 43H(C)
46
H(F) 45H(E)
32
H(2) 31H(1)
34
H(4) 33H(3)
00
H 35H(5)
2nd word
3rd word
4th word
5th word
6th word
1st word
High-order byte Low-order byte
'ABCDEF12345'
2nd word
3rd word
4th word
1st word42
H(B) 41H(A)
44
H(D) 43H(C)
35
H(5) 34H(4)
00H
High-order byte Low-order byte
n2
n1
s
n1
s
n2
s
d
d
d
d

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
SeriesMELSEC Q Series
TypeModular PLC
Programming SoftwareGX Works2, GX Works3
CategoryProgrammable Logic Controller (PLC)
I/O ModulesDigital I/O, Analog I/O, High-Speed Counter, Positioning
CommunicationEthernet, CC-Link
Programming LanguagesLadder Logic, Structured Text, Function Block Diagram, Sequential Function Chart, Instruction List
MemoryFlash Memory
I/O PointsUp to 4096 points (expandable with additional modules)
Power SupplyAC or DC power supply options available, depending on the base unit and modules.
MountingDIN rail mounting
Operating Temperature0°C to 55°C
Storage Temperature-25°C to 75°C
Humidity5% to 95% (non-condensing)
Vibration Resistance10 to 57 Hz, 0.075mm amplitude
WeightVaries depending on the module, from a few grams to several kilograms.
Shock Resistance147 m/s² (3 times each in X, Y, Z directions)