3.7 Precautions on Programming
3.7.1 Precautions on assigning a name
3-11
3
FUNCTIONS
(8) An elementary data type name cannot be used.
(9) Part names of function/FB cannot be used.
Reserved words list
Table 3.7-1 Reserved words (1/2)
Category Character string
Class identifier
VAR, VAR_RETAIN, VAR_ACCESS, VAR_CONSTANT, VAR_CONSTANT_RETAIN, VAR_INPUT, VAR_INPUT_RETAIN,
VAR_OUTPUT, VAR_OUTPUT_RETAIN, VAR_IN_OUT, VAR_IN_EXT, VAR_EXTERNAL, VAR_EXTERNAL_CONSTANT,
VAR_EXTERNAL_CONSTANT_RETAIN, VAR_EXTERNAL_RETAIN, VAR_GLOBAL, VAR_GLOBAL_CONSTANT,
VAR_GLOBAL_CONSTANT_RETAIN, VAR_GLOBAL_RETAIN
Data type
BOOL, BYTE, INT, SINT, DINT, LINT, UINT, USINT, UDINT, ULINT, WORD, DWORD, LWORD, ARRAY, REAL,
LREAL, TIME, STRING
Data type hierachy ANY, ANY_NUM, ANY_BIT, ANY_REAL, ANY_INT, ANY_DATE, ANY_SIMPLE, ANY16, ANY32
Device name
X, Y, D, M, T, B, C, F, L, P, V, Z, W, I, N, U, J, K, H, E, A, SD, SM, SW, SB, FX, FY,
DX, DY, FD, TR, BL, SG, VD, ZR, ZZ
Character string
recognized as device
(Device name +
Numeral)
Such as X0
ST operator NOT, MOD
IL operator
LD, LDN, ST, STN, S, S1, R, R1, AND, ANDN, OR, ORN, XOR, XORN, ADD, SUB, MUL, DIV, GT, GE, EQ,
NE, LE, LT, JMP, JMPC, JMPCN, CAL, CALC, CALCN, RET, RETC, RETCN, LDI, LDP, LDF, ANI, ANDP,
ANDF, ANB, ORI, ORP, ORF, ORB, MPS, MRD, MPP, INV, MEP, MEF, EGP, EGF, OUT(H), SET, RST, PLS,
PLF, FF, DELTA(P), SFT(P), MC, MCR, STOP, PAGE, NOP, NOPLF
Application instruction
in GX Works2
Application instructions such as DMOD, PCHK, INC(P)
QCPU (Q Mode)/QnACPU Programming Manual (Common Instructions), QCPU Structured Programming Manual (Common
Instructions)
SFC instruction
SFCP, SFCPEND, BLOCK, BEND, TRANL, TRANO, TRANA, TRANC, TRANCA, TRANOA, SEND, TRANOC, TRANOCA,
TRANCO, TRANCOC, STEPN, STEPD, STEPSC, STEPSE, STEPST, STEPR, STEPC, STEPG, STEPI, STEPID,
STEPISC, STEPISE, STEPIST, STEPIR, TRANJ, TRANOJ, TRANOCJ, TRANCJ, TRANCOJ, TRANCOCJ
ST code body
RETURN, IF, THEN, ELSE, ELSIF, END_IF, CASE, OF, END_CASE, FOR, TO, BY, DO, END_FOR, WHILE,
END_WHILE, REPEAT, UNTIL, END_REPEAT, EXIT, TYPE, END_TYPE, STRUCT, END_STRUCT, RETAIN,
VAR_ACCESS, END_VAR, FUNCTION, END_FUNCTION, FUCTION_BLOCK, END_FUCTION_BLOCK, STEP,
INITIAL_STEP, END_STEP, TRANSITION, END_TRANSITION, FROM, TO, UNTILWHILE
Standard function name Function names in application functions such as AND_E, NOT_E

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC Q Series and is the answer not in the manual?

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC Q Series
CategoryController
LanguageEnglish

Related product manuals