5-12
5.1 Type Conversion Functions
5.1.4 Bit type
time type conversion
BOOL_TO_TIME(_E)
Operation Error
No operation error occurs in the execution of the BOOL_TO_TIME(_E) function.
Program Example
The program which converts bit type data input to into time type data, and outputs the
operation result from .
(a) Function without EN/ENO (BOOL_TO_TIME)
[Structured ladder]
[ST]
g_time1 := BOOL_TO_TIME (g_bool1);
(b) Function with EN/ENO (BOOL_TO_TIME_E)
[Structured ladder]
[ST]
g_bool3 := BOOL_TO_TIME_E (g_bool1, g_bool2, g_time1);