K
Kristin RamosSep 4, 2025
What does memory error 2 mean on Mitsubishi Amplifier?
- JJesse CrawfordSep 5, 2025
Memory error 2 (EEP-ROM) on your Mitsubishi Amplifier can occur due to: * EEP-ROM error at power on. * EEP-ROM error during operation.
What does memory error 2 mean on Mitsubishi Amplifier?
Memory error 2 (EEP-ROM) on your Mitsubishi Amplifier can occur due to: * EEP-ROM error at power on. * EEP-ROM error during operation.
Why does my Mitsubishi MR-J4-10A Amplifier show an overvoltage error?
An overvoltage error in your Mitsubishi Amplifier is due to a main circuit voltage error.
What does encoder normal communication error 2 mean on Mitsubishi MR-J4-10A?
Encoder normal communication error 2 on your Mitsubishi Amplifier can be caused by: * Encoder data error 1. * Encoder data update error. * Encoder data waveform error. * Encoder non-signal error. * Encoder hardware error 1. * Encoder hardware error 2. * Encoder data error 2.
What causes a servo control error on my Mitsubishi MR-J4-10A Amplifier?
A servo control error on your Mitsubishi Amplifier (specifically for linear servo motors and direct drive motors) can be caused by: * Servo control error by position deviation. * Servo control error by speed deviation. * Servo control error by torque/thrust deviation. * Fully closed loop control error by position deviation. * Fully closed loop control error by speed deviation. * Fully closed loop control error by position deviation during command stop.
What does a board error on my Mitsubishi MR-J4-10A mean?
A board error on your Mitsubishi Amplifier indicates: * Board error 1. * Board error 2. * Board error 3.
What causes a regenerative error in my Mitsubishi MR-J4-10A Amplifier?
A regenerative error in your Mitsubishi Amplifier can stem from: * Regeneration heat error. * Regeneration signal error. * Regeneration feedback signal error.
What does parameter error mean on my Mitsubishi MR-J4-10A?
A parameter error on your Mitsubishi Amplifier indicates either a parameter setting range error or a parameter combination error.
What causes undervoltage on Mitsubishi Amplifier?
Undervoltage in your Mitsubishi Amplifier can be due to: * Voltage drop in the control circuit power. * Voltage drop in the main circuit power.
Why is my Mitsubishi MR-J4-10A showing a servo motor overheat error?
A servo motor overheat error in your Mitsubishi Amplifier can be due to: * Abnormal temperature of servo motor 1. * Abnormal temperature of servo motor 2. * Thermistor disconnected error. * Abnormal temperature of servo motor 3. * Abnormal temperature of servo motor 4.
What causes a main circuit error in my Mitsubishi Amplifier?
A main circuit error in your Mitsubishi Amplifier can occur due to: * A ground fault detected by the hardware detection circuit. * A ground fault detected by the software detection function.
Series | MR-J4 |
---|---|
Type | AC Servo Amplifier |
Model | MR-J4-10A |
Voltage Class | 200V |
Position Control | Yes |
Speed Control | Yes |
Torque Control | Yes |
Full-closed control | Yes |
Communication | SSCNET III/H |
Dynamic brake | Built-in |
Ambient temperature | 0 to 55 °C |
Vibration resistance | 5.9 m/s² |
Rated output current | 0.6 A |
Cooling Method | Natural Cooling |
Rated Output | 0.1 kW |
Input Voltage | 200V |
Output Voltage | 200V |
Control Mode | Position control, Speed control, Torque control |
Protection Functions | Overvoltage, Undervoltage |
Control Method | Sine wave PWM control |
Ambient humidity | Up to 90% (No condensation) |