11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 7
(2) 400 V class
Regenerative power [W]
Servo amplifier
Built-in
regenerative
resistor
MR-
RB1H-4
[82 Ω]
(Note 1)
MR-
RB3M-4
[120 Ω]
(Note 1)
MR-
RB3G-4
[47 Ω]
(Note 1)
MR-
RB5G-4
[47 Ω]
(Note 1)
MR-
RB34-4
[26 Ω]
(Note 1)
MR-
RB54-4
[26 Ω]
(Note 1)
MR-
RB3U-4
[22 Ω]
(Note 1)
MR-
RB5U-4
[22 Ω]
MR-J4-60A4(-RJ) 15 100 300
MR-J4-100A4(-RJ) 15 100 300
MR-J4-200A4(-RJ) 100 300 500
MR-J4-350A4(-RJ) 100 300 500
MR-J4-500A4(-RJ) 130 300 500
MR-J4-700A4(-RJ) 170 300 500
(Note 2) Regenerative power [W]
Servo amplifier
External
regenerative
resistor
(accessory)
MR-RB5K-4
[10 Ω]
MR-RB6K-4
[10 Ω]
MR-J4-11KA4(-RJ) 500 (800) 500 (800)
MR-J4-15KA4(-RJ) 850 (1300) 850 (1300)
MR-J4-22KA4(-RJ) 850 (1300) 850 (1300)
Note 1. Always install a cooling fan.
2. Values in parentheses assume the installation of a cooling fan.