OC275-31
2-8 Wireless remote controller pair number setting operation
ON/OFF
TEMP
FAN
VANE
MODE
CHECK
LOUVER
TEST RUN
AUTO STOP
AUTO START
h
min
RESET
SET
CLOCK
MODEL SELECT
4
A
Model No.
3
2,5
1 Turn on the main power to the unit.
2 Press the SET button with the point of a ball-point pen or the like.
Start this operation from the status of remote controller display turned off.
blinks and Model No. is lighted.
3 Press the button twice continuously.
A Pair No. “0” blinks.
4 Press the temp button to set the pair number you want to set.
5 Press the SET button with the point of a ball-point pen or the like.
Set pair number is lighted for three seconds then turned off.
MODEL SELECT
min
A Pair No. of wireless
remote controller
Indoor PC board
0
1
2
3~9
Factory setting
Cut J41
Cut J42
Cut J41, J42
OC275--2.qxp 01/12/14 3:07 PM Page 31