EasyManua.ls Logo

Mitsubishi PK24FL3 - 3. WRONG WIRING ON SITE; 4. HOW TO CHECK THE PARTS

Mitsubishi PK24FL3
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OC275-34
3. WRONG WIRING ON SITE
Symptom due to wrong wiring between indoor and outdoor units
4. HOW TO CHECK THE PARTS
Wrong wiring Thermostat Phenomena
Outdoor unitIndoor unit
1
2
1
2
OFF The outdoor unit stops.
ON
Operation stops. 9 minutes later, the check code ¨P8¨ appears
on the remote controller display.
OFF Operation stops.
ON
9 minutes later, the check code ¨P8¨ appears on the remote con-
troller display.
Disconnect between 1 and 1 or 2 and
2.
Room temperature
thermistor (RT1)
Pipe temperature
thermistor (RT2)
Fan motor (MF)
Disconnect the connector, then measure the resistance using a tester.
(Surrounding temperature 50°F to 86°F)
Measure the resistance between the terminals using a tester.
Opening and closing temperature of protector.
Open: 266i41°F (Fan motor OFF)
Close: 176i68°F (Fan motor ON)
Normal
4.3k' to 9.6k'
Abnormal
Open or short
Motor terminal
or
Relay connector
Normal
PK
18,24FL3
Abnormal
Red-White
99.5'i10%
Open or short
White-Black
103.5'i10%
1
1
3
3
5
5
Red
White
Black
Relay connector
Protector
Parts name Check points
30,36FL3
62.6'i10%
74.0'i10%
Vane motor (MV)
Measure the resistance between the terminals using a tester.
(Surrounding temperature 68°F to 86°F)
Normal
186 to 214'
Abnormal
Open or short
3 6 1
4
5
2
M
Pink
Connector
Red
Orange
Blue
Brown
Yellow
Brown-Yellow
Brown-Blue
Red-Orange
Red-Pink
OC275--2.qxp 01/12/14 3:07 PM Page 34