15
Cooling
18,000
5,300
2.44
0.14
0.65
0.72
10.26 / 3.70
Heating
20,300 (25,100)
5,950 (7,350)
2.40 (3.80)
0.10 <1.40>
0.45 <5.83>
0.50 <5.83>
10.57 / 3.82
PLH-P2KAH.UK / PLH-P2KAH
1.UK
Single phase, 50Hz, 220-230-240V
Galvanized sheets with gray heat insulation
Plate fin coil
Turbo fan (direct) x 1
0.030
13-14-15-16 (459-494-530-565)
0 (direct blow)
<1.4>
Remote controller & built-in
32-34-35.5-37
32 (1-1/4)
PUH-P2VGAA.UK / PUH-P2YGAA.UK
Single phase, 50Hz, 220-230-240V / 3 phases, 50Hz, 380-400-415V (4wires)
62 / 31
Munsell 5Y 7/1
Linear Expansion Valve
Hermetic
NE36VMJMT / NE36YEKMT
1.6
Line start
Internal thermostat, HP switch, Discharge thermo. / Thermal relay, HP switch, Discharge thermo.
38
Plate fin coil
Propeller (direct) x 1
0.070
55 (1,940)
Reverse cycle
48
49
900 (35-7/16)
330+20 (13+3/4)
855 (33-5/8)
71 (157)
R407C
2.6 (5.7)
1.2 (Ester) MEL56
9.52 (3/8)
15.88 (5/8)
Flared
Flared
Max. 40m
Max. 40m
UNIT : 660 (26) PANEL : 760 (30)
UNIT : 660 (26) PANEL : 760 (30)
UNIT : 253 (10) PANEL : 30 (1-3/16)
UNIT : 20 (44) PANEL : 3.7 (8)
Service Ref.
Item
Btu/h
W
kW
kW
A
A
kW
K/min (CFM)
Pa (mmAq)
kW
dB
mm (in.)
mm (in.)
mm (in.)
mm (in.)
kg (lbs)
A
A
kW
W
kW
K
/min (CFM
)
dB
dB
mm (in.)
mm (in.)
mm (in.)
kg (lbs)
kg (lbs)
L
mm (in.)
mm (in.)
Function
Capacity w1
Total input w1
Service Ref.
Power supply (phase, cycle,voltage)
Input w2
Running current w2
Starting current w2
External finish
Heat exchanger
Fan Fan (drive) x No.
Fan motor output
Airflow
(Low-Medium2-Medium1-High)
External static pressure
Booster heater w2
Operation control & Thermostat
Noise level
(Low-Medium2-Medium1-High)
Unit drain pipe I.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
Running current
Starting current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Crankcase heater
Heat exchanger
Fan Fan (drive) x No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil (Model)
Pipe size O.D.
Connection method
Between the indoor &
outdoor unit
INDOOR UNITOUTDOOR UNIT
REFRIGERANT PIPING
PLH-P2KAH.UK / PLH-P2KAH1.UK
W
D
H
Cooling
Heating
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
Notes 1. Rating Conditions (ISO T1)
Cooling : Indoor : D.B. 27˚C (80˚F) W.B. 19˚C (66˚F) Outdoor : D.B. 35˚C (95˚F) W.B. 24˚C (75˚F)
Heating : Indoor : D.B. 20˚C (68˚F) Outdoor : D.B. 7˚C (45˚F) W.B. 6˚C (43˚F)
Refrigerant piping length (one way) : 5m (16ft)
2. Guaranteed operating range
3. Above data based on indicated voltage
Indoor Unit 1 phase 240V 50Hz
Outdoor Unit 1 phase 240V 50Hz / 3 phase 415V 50Hz
w1 : ( ) Shows the total rating.
w2 : < > Shows the only booster heater rating.
Upper limit
Lower limit
Upper limit
Lower limit
Indoor
Outdoor
Cooling
Heating
D.B. 35˚C W.B. 22.5˚C
D.B. 19˚C W.B. 15˚C
D.B. 28˚C
D.B. 17˚C
D.B. 46˚C
D.B. -5˚C
D.B. 24˚C W.B. 18˚C
D.B. -11˚C W.B. -12˚C
OC235B---1.qxp 04.9.29 3:22 PM Page 15