82
Function Settings
No.
Mode
No.
Setting
: Initial setting
(
Factory setting
)
- : Not available
4-Way
cassette
PLA-BA
Filter sign 100h 1
2500h 07 2
No filter sign indicator
3
Air flow
Quiet
1
(
Fan speed
)
Standard
08 2
High ceiling
3
No.of air outlets 4 directions 1
3 directions 09 2
2 directions
3
Optional high efficiency
Not supported
10
1
filter
Supported
2
Vane setting
No vanes
(
Vane No.3 setting : PLA only
)
1
Vane No.1 setting
11 2
Vane No.2 setting
3
Optional humidifier
Not supported
13
1
(
PLA only
)
Supported
2
Vane differential setting
No.1 setting
(
TH5: 24-28:
)
1
in heating mode
No.2 setting
(
Standard
,
TH5:28-32:
)
14 2
(
cold wind prevention
)
No.3 setting
(
TH5: 32-38:
)
3
Swing
Not available Swing
23
1
Available Wave air flow
2
Set temperature in heating
Available
24
1
mode
(
4 deg up
)
Not available
2
Fan speed during the Extra low 1
heating thermo OFF
Stop
25 2
Set fan speed
3
Fan speed during the
Set fan speed
27
1
cooling thermo OFF
Stop
2
Detection of abnormality of
Available
28
1
the pipe temperature
(
P8
)
Not available
2
}
PLA-BA
(2) Functions available when setting the unit number to 01-03 or AL (07 in the case of wireless remote controller)
• When setting functions for an indoor unit in an independent system, set the unit number to 01 referring to 4 setting the
indoor unit number of Operating Procedure.
•
When setting functions for a simultaneous- Twin Triple indoor unit system, set the unit number to 01 to 03 for each indoor unit
in the case of selecting different functions for each unit referring to 4 setting the indoor unit number of Operating Procedure.
• When setting the same functions for an entire simultaneous Twin Triple-indoor unit system, set refrigerant address to AL (07
in the case of wireless remote controller) referring to 4 setting the indoor unit number of Operating Procedure.
<Table 4> Available functions and settings for PEAD-SP
•
JA(L)
Function Settings
No.
Mode
No.
Setting
: Initial setting
(
Factory setting
)
Filter sign 100h 1
2500h 07 2
No filter sign indicator
3
External static pressure
35/50/70/100/150Pa
08
10
1
2
Extra low
3
Fan speed during the
heating thermo OFF
Stop
25
1
Set fan speed
2
27
1
2
Detection of abnormality
of the pipe
1
28
2
Set temperature in heating
24
mode
(
4 deg up
)
Refer to the right table
External static pressure
35/50/70/100/150Pa
Refer to the right table
Available
Not available
Fan speed during the
cooling thermo OFF
Set fan speed
Stop
Available
Not available
External static
pressure
Setting No.
Initial setting
(
Factory setting
)
35Pa
50Pa
70Pa
100Pa
150Pa
2
3
1
2
3
Mode No. 08 Mode No. 10
1
1
2
2
2
<Table 3> Available functions and settings for PLA-BA