SW1 setting
12345678
00010001
10010001
01010001
11010001
00110001
10110001
01110001
11110001
00001001
10001001
01001001
00000011
10000011
01000011
11000011
00100011
10100011
01100011
11100011
00010011
10010011
01010011
11010011
00110011
10110011
01110011
11110011
00001011
10001011
01001011
High-pressure sensor data at time of abnormality delay
TH1 sensor data at abnormality delay
TH2 sensor data at abnormality delay
TH5 sensor data at abnormality delay
THHS sensor data at abnormality delay
Outdoor SC (cooling) at abnormality delay
SC/SH (No.1 indoor unit) at abnormality delay
SC/SH (No.2 indoor unit) at abnormality delay
SC/SH (No.3 indoor unit) at abnormality delay
SC/SH (No.4 indoor unit) at abnormality delay
SC/SH (No.5 indoor unit) at abnormality delay
Actual frequency at time of abnormality
Fan step number at time of abnormality
Openness of outdoor SLEV at time of abnormality
Openness of LEV at time of abnormality (No.1 unit)
Openness of LEV at time of abnormality (No.2 unit)
Openness of LEV at time of abnormality (No.3 unit)
Openness of LEV at time of abnormality (No.4 unit)
Openness of LEV at time of abnormality (No.5 unit)
High-pressure sensor data at abnormality delay
TH 1 sensor data at time of abnormality
TH 2
sensor data at time of abnormality
TH 5
sensor data at time of abnormality
THHS
sensor data at time of abnormality
Outdoor SC (Cooling) at time of abnormality
Indoor SC/SH (No. 1) at time of abnormality
Indoor SC/SH (No. 2) at time of abnormality
Indoor SC/SH (No. 3) at time of abnormality
Indoor SC/SH (No. 4) at time of abnormality
Indoor SC/SH (No. 5) at time of abnormality
1
2345 6
78
Display on the LD1 (display data)
Display of data from high-pressure sensor,
all thermistors, and SC/SH at abnormality
delay
Display of actual frequency at time of abnormality
Display of fan step number at time of abnormality
Display of openness (pulses) of outdoor
SLEV and indoor LEV at time of abnormality
Display of data from high-pressure sensor
and all thermistors at time of abnormality
Display of data from SC/SH and all
thermistors at time of abnormality
-99.9 ~ 999.9 (short circuit/open: -99.9 or 999.9)
0~FF(16progressive)
0~20
0~2000
-99.9 ~ 999.9 (short circuit/open: -99.9 or 999.9)
No.
Display mode Notes
OC183E--4.qxp 10.5.6 0:54 PM Page 101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi PUMY-71VM and is the answer not in the manual?

Mitsubishi PUMY-71VM Specifications

General IconGeneral
BrandMitsubishi
ModelPUMY-71VM
CategoryAir Conditioner
LanguageEnglish

Related product manuals