Mitsubishi PUMY-71VM User Manual

Mitsubishi PUMY-71VM
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
102
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
SW1 setting
12345678
11001011
00101011
10101011
01101011
11101011
00011011
10011011
01011011
11011011
00111011
10111011
01111011
11111011
00000111
10000111
01000111
11000111
00100111
10100111
01100111
11100111
00010111
10010111
01010111
11010111
00110111
10110111
01110111
11110111
00001111
10001111
01001111
11001111
00101111
10101111
01101111
Capacity code (No.6 indoor unit)
Capacity code (No.7 indoor unit)
Capacity code (No.8 indoor unit)
Indoor unit mode (No.6 unit)
Indoor unit mode (No.7 unit)
Indoor unit mode (No.8 unit)
Indoor LEV opening (No.6 unit)
Indoor LEV opening (No.7 unit)
Indoor LEV opening (No.8 unit)
TH23 (No.6 indoor unit)
TH23 (No.7 indoor unit)
TH23 (No.8 indoor unit)
TH22 (No.6 indoor unit)
TH22 (No.7 indoor unit)
TH22 (No.8 indoor unit)
TH21 (No.6 indoor unit)
TH21 (No.7 indoor unit)
TH21 (No.8 indoor unit)
Indoor SC/SH (No.6 indoor unit)
Indoor SC/SH (No.7 indoor unit)
Indoor SC/SH (No.8 indoor unit)
Target indoor SC/SH (No.6 unit)
Target indoor SC/SH (No.7 unit)
Target indoor SC/SH (No.8 unit)
Valve position at abnormality delay (LEV:No.6 Indoor unit)
Valve position at abnormality delay (LEV:No.7 Indoor unit)
Valve position at abnormality delay (LEV:No.8 Indoor unit)
SC/SH (No.6 indoor unit) at abnormality delay
SC/SH (No.7 indoor unit) at abnormality delay
SC/SH (No.8 indoor unit) at abnormality delay
Openness of LEV at time of abnormality (No.6 unit)
Openness of LEV at time of abnormality (No.7 unit)
Openness of LEV at time of abnormality (No.8 unit)
Indoor SC/SH (No.6) at time of abnormality
Indoor SC/SH (No.7) at time of abnormality
Indoor SC/SH (No.8) at time of abnormality
1
2345 6
78
Display on the LD1 (display data)
Display of indoor unit capacity mode
Display of indoor unit operating mode
Display of openness (pulses) of outdoor
SLEV and indoor LEV
Display of indoor SC/SH data
Display of all control target data
Display of openness (pulses) of indoor LEV
at time of abnormality
Display of opeeness (pulses) of indoor LEV
at time of abnormality
0~255
OFF Fan
Cooling
thermo
ON
Cooling
thermo
OFF
Heating
thermo
ON
Heating
thermo
OFF
No.
Display mode Notes
0~2000
0~2000
0~2000
-99.9 ~ 999.9 (short circuit/open: -99.9 or 999.9)
-99.9 ~ 999.9 (short circuit/open: -99.9 or 999.9)
-99.9 ~ 999.9 (short circuit/open: -99.9 or 999.9)
SCm/SHm (0.0~14.0)
-99.9 ~ 999.9 (short circuit/open: -99.9 or 999.9)
during heating:supercooling (SC)/during cooling:overtheating (SH)
OC183E--4.qxp 10.5.6 0:54 PM Page 102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi PUMY-71VM and is the answer not in the manual?

Mitsubishi PUMY-71VM Specifications

General IconGeneral
BrandMitsubishi
ModelPUMY-71VM
CategoryAir Conditioner
LanguageEnglish

Related product manuals