EasyManuals Logo

Mitsubishi PUMY-71VM User Manual

Mitsubishi PUMY-71VM
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
43
PUMY-125YM
SMOOTHING CAPACITOR
C03
CAPACITOR <FILTER>
C01,C02
CONNECTOR <DISCHARGE CIRCUIT,POWER SUPPLY>
CNR
RESISTOR <RUSH CURRENT PROTECT>
RS1
RESISTOR <DISCHARGE>
RB1,RB2
RESISTOR <VOLTAGE BALANCE ADJUSTMENT>
RD1,RD2
RELAYX
X73
RELAY <SOLENOID VALVE>
X72
RELAY <4-WAY VALVE>
TERMINAL BLOCK <TRANSMISSION>
C1,C2
FAN MOTOR CAPACITOR
SWITCH <UNIT ADDRESS SELECTION,3RD DIGIT>
SWITCH <UNIT ADDRESS SELECTION,2ND DIGIT>
SWU3
SWU2
SWITCH <UNIT ADDRESS SELECTION,1ST DIGIT>
SWU1
SWITCH <FUNCTION SELECTION>SW5
SWITCH <MODEL SELECTION>SW4
SWITCH <TEST RUN>SW3
THERMISTOR
<IPM RADIATOR PANEL TEMP. DETECTION>
THHS
INTELLIGENT POWER MODULEIPM
FAN CONTROL
F.C
CONNECTOR <CENTRALIZED CONTROL POWER SUPPLY>
CN40
CONNECTOR <FOR STORING JUMPER CONNECTOR>
CN41
CONNECTOR <COMPRESSOR DRIVE SIGNAL OUTPUT>
CN51
CONNECTOR <INVERTER SIGNAL 5V>
CN4
CONNECTOR <POWER SUPPLY 30V,12V,5V>
CN3
CONNECTOR <POWER SYNC SIGNAL,PROTECTION>
CN2
CONNECTOR <CONTROLLER DRIVE CONTROL>
CN1
CONNECTOR <POWER SUPPLY>
CNA
CURRENT DETECTION
ACCT
SYMBOL
NAME
SYMBOL
NAMESYMBOL
NAME
SW2
SW1
SWITCH <FUNCTION SELECTION>
SWITCH <DISPLAY SELECTION>
CONNECTOR <DEMAND SIGNAL/SILENT MODE INPUT>
CN3D
REACTOR
THERMAL SWITCH <COMPRESSOR>
TERMINAL BLOCK <CENTRALIZED CONTROL>
TH2
TH5
TH6
63HS
52C
21S4
TH1
SV1
SLEV
MF1,MF2
LD1
X71
CNS1
CNS2
ZNR
FUSE2
TB7
TB3
TB1
MC
DCL
NF
FUSE1
49C
CONNECTOR <MULTI SYSTEM>
CONNECTOR <CENTRALIZED CONTROL>
FUSE(2A)
DIGITAL INDICATION LED
<OPERATION INSPECTION INDICATION>
FAN MOTOR(INNER THERMOSTAT)
EXPANSION VALVE
SOLENOID COIL <HOT GAS BYPASS>
HIGH PRESSURE SENSOR
<DISCHARGE PRESSURE DETECTION>
MAGNETIC CONTACTOR
4-WAY COIL
RELAY <MAGNETIC CONTACTOR>
VARISTOR
FUSE(6.3A)
COMPRESSOR(INNER THERMOSTAT)
NOISE FILTER
TERMINAL BLOCK <POWER SUPPLY>
THERMISTOR <DISCHARGE TEMP. DETECTION>
THERMISTOR
<LOW PRESSURE SATURATED TEMP. DETECTION>
THERMISTOR <OUTDOOR TEMP. DETECTION>
THERMISTOR
<PIPE TEMP. DETECTION:JUDGING DEFROST>
CB1,CB2
DM
SMOOTHING CAPACITOR
DIODE MODULE
NAME
SYMBOL
9
8
7
6
5
4
3
2
1
0
NO FUSE BREAKER
25A
L1
L2
L3
N
X
X
1
RD2
1
(WHT)
CN3D
(WHT)
CN51
(WHT)
CN41
(WHT)
CN40
53214321
43214321
YLW
CB2
CB1
CNR
(WHT)
CNR
(WHT)
(RED)
CNA
<POWER SUPPLY BOARD>
(YLW)
49C
(RED)
CN1
FUSE1
(6.3A)
FUSE2
(2A)
SLEV
6
1
2
5764
49C
YLW
31 1234567
1234567
12367123456
1236
123671236
CN4
CN3
CN2
CN4CN3CN2
(YLW)
(YLW)
(WHT)
(YLW)
(RED)
(YLW) (WHT)
2
4321
12345678
10987654321
2876543
SW3
SW5
OFF
ON
OFF
ON
SW4
SW1
SW2
OFF
ON
1
1
ON
OFF
ON
OFF
(YLW)
ACCT
654321
132
CN1
3
63HS
654
1321231
13 2121
THHS
TH1TH2TH5TH6
63HS
THHS
TH2
TH6 TH5
TH1
(BLK) (WHT)
(GRN)
(GRN)
(WHT)
(WHT)
SLEV
(WHT)
BLU
-
+
~
~
~
LO1
LO2
LO3
LI3
E
N
LI2
LI1
(RED)
31
CNA
13
GRN
6
YLW
YLW
WHT
BLK
RS1
RB2
RB1
RD1
BLK
RED
BLU
WHT
GRN
E
P
N
C03
C02C01
N
P1PN1
10
3
5
6
8
10
3
568
+
IPM
WV
+
+
RED
WHT
BLK
31 13
31
(BLU)
52C
X71
YLW
YLW
52C
31
(GRN)
21S4
X72
BLU
BLU
21S4
SV1
RED
RED
13
(BLK)
SV1
(WHT)
MF2
(WHT)
MF1
MF1
C1
31
WHT
BLU
WHT
BLU
RED
ORN
RED
ORN
BLU
WHT
31
BLU
52C
N
BLU
L3
BLK
L1
RED
S
M1
M2
S
M2
M1
LD1
SWU1
(1rd digit)
SWU2
(2rd digit)(3rd digit)
SWU3
<RESISTOR BOARD>
CNS1
(RED)
CNS2
(YLW)
F.C
2
1
1
GRN/YLW
ZNR
+
BLU
BLK
2
FOR CENTRALIZED
CONTROL
DC 30V (Non-polar)
WHT
BLK
WHT
RED
WHT
ORN
ORN
BRN
BRN
GROUND
TO INDOOR UNIT
CONNECTING WIRES
DC 30V (Non-polar)
POWER SUPPLY
3N~
380/220-415/240V
50Hz
380/220
60Hz
W
V
U
U
X73
TB3
TB7
L2
TB1
MF2
C2
MC
DCL
DM
NF
<MULTI CONTROLLER BOARD>
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0
1.Refer to the wiring diagrams of the indoor units for details on wiring of each indoor unit.
2.Symbols used in wiring diagram above are. :Terminal block, :Connector, :Insertion tab.
3.Self-diagnosis function
The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch(SW1) and LD1(LED indication)
found on the multi-controller of the outdoor unit.
LED indication : Set all contacts of SW1 to OFF.
7
8
5
6
3
42
1
(Example)
When the compressor and SV1 are
turned during heating operation.
Always lit---
SV1
21S4
1 8
7654
3
52C
2
Compressor operated
Indication
Bit
During normal operation
The LED indicates the drive state of the controller in the outdoor unit.
OC183E--2.qxp 10.5.6 0:46 PM Page 43

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi PUMY-71VM and is the answer not in the manual?

Mitsubishi PUMY-71VM Specifications

General IconGeneral
BrandMitsubishi
ModelPUMY-71VM
CategoryAir Conditioner
LanguageEnglish

Related product manuals